7.0 Optional Extras

13

CE-1-11/00

7.1

Ancillary Equipment

Internal Supply Valve

Ref: SV100

Adjustable supply valve with 80mm long,

100mm diameter spigot connection. Valve

design ensures horizontal discharge of air for

optimum diffusion. Moulded in white plastic, the

EV100 valve is suitable for both ceiling and wall

mounting and is 150mm diameter overall.

Filter

Ref: F100

Coarse in-line filter complete with reticulated

foam element. Compatible with 100mm

diameter ducting.

External Push-Fit Wall Vent

Ref: WC1

400mm long brown plastic duct and external

grille with vaned rubber seal for push fit

installation in external walls. Fits into pre-drilled

hole of 115mm diameter.

External Dual Wall Vent

Ref: WC2

Combined supply and extract terminal with grey

plastic external cowl, with 100mm diameter

ducting. This vent is ideal for exposed

installations.

External Louvre Wall Box

Ref: WL100

Anodized aluminium external weather louvre

with metal wall box 130 x 130mm and 174 x

174mm grille. 100mm diameter spigot

connection.

Ventilating Roof Tiles

Ref: VT100

Moulded ventilation terminal tiles, available in a

range of sizes, profiles and colours. 100mm

diameter spigot connection.

In-Line Heater

Ref: ILH100

Compatible with 100mm ducting, the ILH100

provides a boost heat facility when required.

Flexible Ducting

Ref: AFD100

Aluminium ducting in 10m lengths.

Ref: ACD100

Acoustically insulated ducting in 6m lengths.

Ref: IFD100

Thermally insulated ducting in 6m lengths.

Ref: PFD100

PVC ducting in 6m lengths.

Quicktube 100mm rigid plastic ducting can also

be used in conjunction with the 

HR

100R unit. For

details please see data sheet.

Speed Control Switch

Ref: VCON100

White plastic single gang switch for ON/OFF

control and NORMAL/BOOST speed control of

HR

100R unit.

Speed Control Switch

Ref: NBSW

White plastic single gang switch for

NORMAL/BOOST speed control of 

HR

100R unit.

A metal black box for flushing mounting 

(Ref: MBB) and plastic back box for surface

mounting (Ref: PBB) are available for use with

the above controllers.

Pullcord Control Switch

Ref: PCSW

2 way ceiling mounted switch for

NORMAL/BOOST speed control of 

HR

100R unit.

A second PCSW can also be used for ON/OFF

control.

Humidity Sensor

Ref: HS6

Electronic humidity sensor with changeover

relay output and adjustable switching point from

60% to 100% RH. In built temperature

compensation (night time setback).

Contamination protection sensor.

Timer

Ref: TIM2

Remote mounting timer box to provide ON/OFF

control or switching between the 2 speeds on

operation of switched live. Over-run period

adjustable 2-30 minutes.

Internal Extract/Supply Grille

Ref: ESG100

White plastic louvre grille designed to fit in the

wall or ceiling and serves both extract and

supply functions. 100mm diameter spigot

connection.

Internal Extract Valve 

Ref: EV100

Adjustable extract valve with 80mm long,

100mm diameter spigot connection. Moulded in

white plastic, the EV100 valve is suitable for

both ceiling and wall mounting and is 150mm

diameter overall.

Содержание HR100R

Страница 1: ...CE 1 11 00 HR100R Mini Air Handling Unit For Ducted Ventilation With Heat Recovery Installation and Servicing Instructions Please leave these instructions with the user...

Страница 2: ...CE 1 11 00 2...

Страница 3: ...CE 1 11 00 3 1 0 Introduction 4 2 0 Site Requirements 5 3 0 Installation 6 4 0 Electrical 10 5 0 Commissioning 11 6 0 Maintenance 12 7 0 Optional Extras 13 8 0 Notes 14 Section Page Contents...

Страница 4: ...involving internal bathrooms and meets building regulation requirements for this application A two speed motor provides for constant low rate ventilation with a boost speed option Fresh pre warmed air...

Страница 5: ...ers in the vicinity of excessive levels of airborne oil or grease 7 If the ceiling diffusers are installed in a room containing a fuel burning appliance the installer must ensure that air replacement...

Страница 6: ...or blockboard 19mm preferred This board should be raised enough to facilitate the mounting of the unit above joist level 6 The unit must be positioned so that the condensate outlet can be trapped and...

Страница 7: ...es it is necessary to lift the floor coverings at first floor level above the terminal positions to gain access to the terminal housings to secure and seal the duct and fittings 12 Fix in position all...

Страница 8: ...and 45 diversions and branches are accomplished with flexible fittings QTB90 QTB45 and QTET The duct is a push fit into the socket of the connector and fittings 23 Once assembled the joints are secure...

Страница 9: ...se of flexible ducting should be limited to an absolute minimum If used it should be fully stretched in order to minimse pressure loss 29 Offer the unit on to the mounting surface ensuring that it is...

Страница 10: ...ow Earth 1 2 1 0 2 Continuous Normal Speed Continuous Boost Speed VCON100 Manual Normal to Boost Speed Switching and ON OFF Control NBSW and PCSW Manual Normal to Boost Speed Control HS6 Automatic Nor...

Страница 11: ...two airflows to obtain the overall airflow rates and the individual terminal air flow rates as specified on the air change schedule 3 An airflow meter must be used to set the correct airflows NOTE The...

Страница 12: ...on experienced and according to the following procedure 1 Isolate the mains power supply 2 Remove the four securing screws from either end of the cover 3 Remove the cover 4 Remove the heat exchanger f...

Страница 13: ...in 6m lengths Ref IFD100 Thermally insulated ducting in 6m lengths Ref PFD100 PVC ducting in 6m lengths Quicktube 100mm rigid plastic ducting can also be used in conjunction with the HR100R unit For...

Страница 14: ...8 0 Notes 14 CE 1 11 00...

Страница 15: ...CE 1 11 00 15...

Страница 16: ...CE 1 11 00 Vent Axia Ltd Fleming Way Crawley West sussex RH10 9YX www vent axia com Comp No 370666 Iss C 0310...

Отзывы: