Jumper Configuration
Cooling and Heating - Heat Pump with B reversing valve.
Residential Heat Pumps, split systems & package units, with no auxiliary heat.
OWNER'S MANUAL
OUTPUTS
No Demand
With Demand
Cooling Mode
Heating Mode
Y
,
G
B
Y
,
G
,
B
Y active in Heating
Page 21
-
T0130
Jumper #1 (J1) should be set for
ELEC/HP
,
Jumper #2 (J2) should be set for
HP
,
and
Jumper #3 (J3) should be set for
B
for typical
heat pump operation.
Note: Thermostat does
not have Auxiliary Heat / Emergency Heat
capability.
B
J3
HP
J2
ELEC/HP
J1
PCB: 00597 Rev. AA