Select Input A on the Powerflash Interface.
Locate the input terminals on the Powerflash Interface.
Select the proper mode for your desired operation:
Turns on all lights
connected to Lamp Modules and
Wall Switch Modules, and turns on a selected
Appliance Module.
Flashes all lights
connected to Lamp Modules and
Wall Switch Modules.
Turns on a selected Module
with the same house
and unit code as the Powerflash Interface.
Connect one end of the supplied resistor to the screw
input terminal of the Powerflash Interface. The
supplied resistor will then be wired ‘in-line’ with either
the MISC1, MISC2 or MISC3 output (depending on
which is set to PROG) or the C wire
(see next page)
. It
does not matter which of the two wires you choose.
The resistor is 4.7k ohm, 1/4 watt.
1
9
13
A
E
M
I
5
HOUSE CODE
UNIT CODE
TEST
ALL UNITS OFF
POWERHOUSE
X-10
POWERFLASH
INTERFACE
INPUT
A B
MODE
1 2 3
POWERFLASH
INTERFACE
PF284
Input terminals
Control of the Thermostat’s Auxiliary Output
cont.
Connect the thermostat to the Powerflash Interface as follows: