 Part#’s: 0612 & 0616

Page 11

Unpacking

Carefully remove the carton and plastic-wrap from the Venom BCMS and inspect it for any damage that may have 
occurred in transit. If your unit is damaged, notify the delivery carrier immediately and retain the entire shipment 
intact for inspection by the carrier.

DO NOT RETURN GOODS WITHOUT THE PRIOR AUTHORIZATION OF VENOM. 
IF YOUR VENOM BCMS WAS DAMAGED IN TRANSIT, YOU MUST FILE A CLAIM DIRECTLY WITH THE FREIGHT CARRIER. 
VENOM IS NOT RESPONSIBLE FOR SHIPPING DAMAGES.

Do not discard the shipping carton or packing material for your Venom BCMS until you have checked all of the 
components and installed and tested the unit. It is advisable to keep the shipping container and packaging 
components in case shipping is required in the future.

Installation

Prior to installing your Venom BCMS make sure you have read and fully understand the enclosure, electrical and 
venting requirements sections of this manual. DO NOT proceed with installation until the proper power is available 
at the install location and you have also determined the proper venting as required by your particular 
circumstances and jurisdictional regulations.

When planning your installation keep in mind that you will need room for the computer that will be used to control 
your Venom BCMS. You can do this by installing a shelf in the enclosure to hold a desktop computer and monitor or 
a simple slide out tray can be used to house a laptop computer. This machine will need a constant internet 

connection to be most effective and you may also want to plan for this during your installation preparation. 

 
Install the Venom BCMS system in the chosen enclosure taking care to ensure that all requirements outlined in the 
enclosure requirements section of this manual are met. Please also take care to allow adequate clearance for 
routing of the necessary cabling and ducting.

First secure the face of the Venom BCMS to the enclosure using the proper hardware for your specific enclosure 

(not included with the Venom BCMS).

CAUTION

TWO PERSON LIFT REQUIRED

Содержание 0612

Страница 1: ...ng LiPo batteries can be hazardous Read this manual in its entirety before attempting to use this product BCMS PRO AND BCMS ULTRA Innovative Safety Features Flexible Scalable to the Needs of Your Oper...

Страница 2: ...______________________________________ 9 Chapter III Getting Started Included Required Items________________________________________________________________10 Unpacking________________________________...

Страница 3: ...u for purchasing a Venom Commercial Series BCMS Battery Charger Management System This system is the rst of its kind allowing users to easily catalog manage and maintain a eet of batteries from one ea...

Страница 4: ...bration 14 Do not disassemble modify or attempt any form of repair of this charger Cautions Warnings Cont System Overview The Venom Commercial Series BCMS Battery Charging Management System allows use...

Страница 5: ...USB port for charging mobile devices 6U rack mountable with adjustable rear brackets for added support Proudly designed developed and assembled in the USA Patent pending Simpli ed battery con guration...

Страница 6: ...Part s 0612 0616 Page 4 3 88 98 4 8 75 222 3 18 31 465 1 19 00 482 6 29 00 736 6 MAX 24 00 609 6 MIN 10 47 265 9 21 48 545 6 23 84 605 5 4 06 103 2 16 92 429 8 1 75 44 5 Mechanical Drawings...

Страница 7: ...Part s 0612 0616 Page 5 Mechanical Drawings Cont 3 83 97 2 5 44 138 1 9 50 241 3 5 9 3 4 0 0 1 8 5 4 4 6 1 1 8 42 213 9 5 6 0 5 6 1 14 00 355 6 11 60 294 6 15 71 399 1...

Страница 8: ...2 C19 110V 240VAC Input Front 1 2 3 4 9 10 11 5 6 6 7 8 1 Charge Button 2 Storage Button 3 LCD Display 4 On O Switch 9 Battery Bay Latches 10 Battery Bay LED Indicator 11 Enclosure Mounting Holes 5 U...

Страница 9: ...ST XH Balance Connector Port 3 3 JST GH Communicator Port compatible with Venom Commercial Series Batteries 4 4 XT90 Charge Connector Port 5 5 Battery Bay to Charger Chassis Interface Connector Side 1...

Страница 10: ...ch utilizes standard 19 spacing width We recommend considering the nal installation weight of a single Venom BCMS to be 100lbs and the selected enclosure must be rated for the appropriate weight handl...

Страница 11: ...ior wall The use of any piping other than 4 should be avoided to keep the system in negative pressure as the ventilation system serves only to evacuate smoke generated during a catastrophic battery ev...

Страница 12: ...Allen Key Hex Screw x8 Washer x8 Lock Washer x8 240VAC IEC C19 to L6 20P 0616 Only Venom Balance Block w Extended Leads JST XH x4 USB A to USB B cable USB Hub optional Enclosure and mounting hardware...

Страница 13: ...ons of this manual DO NOT proceed with installation until the proper power is available at the install location and you have also determined the proper venting as required by your particular circumsta...

Страница 14: ...CMS power cord to the appropriate outlet and connecting the USB cable to the computer that will run the Venom BCMS software Please note that multiple systems can be connected to a single computer via...

Страница 15: ...and USB driver image 4 6 Complete the steps required for installation of the desktop app and USB driver The USB driver must be installed for the desktop app to communicate properly with the Venom BCMS...

Страница 16: ...n gured bays Batteries will be charged or discharged until their con gured target storage voltage is reached The target storage voltage is set in the battery con guration panel of the Venom BCMS softw...

Страница 17: ...serted Connecting Battery is detected but not con gured Idle Battery connected not charging or discharging Charging Battery is charging Storage Battery is charging or discharging to storage voltage Ba...

Страница 18: ...acks that are used outside of normal operating parameters If you are unsure about how to use or handle any of our products contact Venom for assistance Limitation of Liability VENOM WILL NOT BE SUBJEC...

Страница 19: ...comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is o...

Страница 20: ...ada VENOM POWER 14028 N Ohio Street Rathdrum Idaho 83858 United States of America CUSTOMER SERVICE For quick customer support please visit venompower com or call 800 705 0620 Copyright 2018 Venom Grou...

Отзывы: