4. CONTROLS (
CONT
’
D
)
14
4.2 E
LECTRICAL
C
ONNECTION
TO
O
PTIONAL
W
ALL
C
ONTROL
Use the terminal connector included in the installation kit to perform the electrical
connection for main and optional wall controls. Check if all wires are correctly inserted
in their corresponding holes in the terminal block. (A wire is correctly inserted when its
orange receptacle is lower than another one without wire. On picture at right, wire
A
is
correctly inserted, but not wire
B
.)
VE0106
A
B
4.2.1 E
LECTRICAL
C
ONNECTION
TO
A
LTITUDE
M
AIN
W
ALL
C
ONTROL
(E
XCLUSIVELY
FOR
S
OLO
UNITS
)
NO C NC I OC OL Y R G B
VE0175
SMART
SET
MODE
PREF
4.2.2 E
LECTRICAL
C
ONNECTION
TO
D
ECO
-
TOUCH
M
AIN
W
ALL
C
ONTROL
(
A
LL
UNITS
)
NO C NC I OC OL Y R G B
VE0250
Once the wall control(s) connections have been made, insert the terminal connector in the electrical
compartment front face.
NOTE: For information about the operation of the wall controls, refer to the user guide.
VD0278
T
ERMINAL
CONNECTOR
LOCATION
For more convenience, this unit can also be controlled using an optional main wall control.
WARNING
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical
shock or damage of the wall control or electronic module inside the unit.
!
CAUTION
Never install more than one optional main wall control per unit. Make sure that the wires do not short-circuit
between themselves or by touching any other components on the wall control. Avoid poor wiring connections. To
reduce electrical interference (noise) potential, do not run wall control wiring next to control contactors or near
light dimming circuits, electrical motors, dwelling/building power or lighting wiring, or power distribution panel.