3. Slide the upper flue up to the
ceiling and secure it to the
mounting plate using 2 no. 8 x
1/2" quadrex screws (
1
).
NOTE: Ensure flue seam is
facing the opposite
control side of the hood.
Carefully slide the lower flue
over the upper flue up to the
ceiling and have the second
person hold it to the ceiling (
2
)
while performing step 4.
CAUTION
DO NOT REMOVE the protective plastic film covering the decorative flue (upper
and lower) and the hood yet.
9. INSTALL HOOD
BE CAREFUL when installing the decorative flue and hood, they may have
sharp edges.
WARNING
!
- 11 -
1. Attach blower box assembly to lower angle
brackets using 16 no. 10-32 x 1/2" quadrex
screws (4 per angle brackets). Connect
hood duct to ceiling duct and seal joint with
metal foil duct tape.
NOTE: Ensure electrical channel is face to
where the front of the hood will be
positioned.
2. Run house wiring through wire clamp into
blower box electrical channel. Tighten wire
clamp to secure house wiring cable to
blower box.
NOTE: The length between the top of the
blower box and the bottom of the
hood is 12³⁄
16
".
HD0424
H
OUSE WIRING
HD042
3
1
2