LOCATING THE POWER UNIT

•  Locate the power unit away from the general living area in 

an accessible location for cleaning and maintenance.

•  Locate the power unit within 6 feet of a grounded electrical outlet. 

The power unit requires a 120 VAC power source, dedicated 
15-amp branch circuit.

•  Do not locate the power unit close to a source of extreme 

heat (i.e.: water heater) or in an area with a high ambient 
temperature (i.e.: attic, furnace room).

•  If the power unit is located in a closet or a small utility 

room, make sure the area is well-ventilated (e.g.: with door 
louvers).

CHANGING INTAKE LINE DIRECTION

The intake line connects to the right side of the unit. However, 
it is possible to change this configuration; to connect the intake 

line to the left side of the unit, follow these steps:

 

 Remove debris pail from power unit by releasing both latches 

on sides of the unit, pulling them out and then pushing up. 
Detach the pail from unit. 

 

550VF1 only

: Grasp 

the edges of the bag 
collar and pull down; 
the bag will slide off 
easily. 

Do not pull on 

the bag

. Set the bag 

aside.

 

550VF1 only

: Using 

a Phillips screwdriver 
no. 2, remove the 
screw tightening the 
bag adapter and 
intake elbow junction.
Disassemble the 
bag adapter from the 
intake elbow and set 
aside with its screw 
and nut.

 

All units

: Disassemble

the intake elbow from 
the back of the unit 
using a 3/8” socket to 
remove both retaining 
nuts and screws.

 

All units

: Flip the 

intake elbow 180°, 
then reassemble it to 
the unit, taking care to 
keep its gasket at its 
original position.

  NOTE: Ensure the 

gasket is not folded in 
order to prevent lack of suction, and noise.

 

550VF1 only

Reassemble the bag 
adapter to the intake 
elbow. Align triangle 
with small inclined 
stud, then tighten 
the junction using 
the screw and nut 
previously removed in 

.

 

550VF1 only

: Put the 

bag back in place by 
grasping the edges of 
its collar and insert 
over bag adapter. Be 
careful not to tear the 
bag. Ensure the collar 
is positioned between 
the taper ring and the 
bag stopper on the 
bag adapter. 

 

All units

: Put the pail back in place.

POWER UNIT INSTALLATION

AD0076

AO0078

550VF1 

ONLY

AD0075

550VF1 

ONLY

AD0077

AD0078

550VF1 

ONLY

AO0080

550VF1 

ONLY

T

APER

 

RING

B

AG

 

STOPPER

    WARNING

!

Do not install outdoors. Before being hung, rest the 
unit on a leveled surface to prevent the unit to fall 
down. When performing installation, servicing or 
cleaning the unit, it is recommended to wear safety 
glasses and gloves.

Содержание 550VF1

Страница 1: ...E FOR RESIDENTIAL USE ONLY REGISTER YOUR PRODUCT ONLINE AT WWW VENMAR CA 24009 rev A AB0039 CENTRAL VACUUM POWER UNITS MODELS SFDB DK SFDB DL AND SFDB DM VENMAR VENTILATION ULC WWW VENMAR CA 1 877 896...

Страница 2: ...not use with damaged cord or plug If appliance is not working as it should if it has been dropped damaged left outdoors or dropped into water return it to a Service Center 12 Keep your work area well...

Страница 3: ...ubing and the outside of the plastic tubing or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE...

Страница 4: ...he center line behind the kick plate through the subfloor Locate the reference hole from beneath the subfloor Cut a 4 x 4 access hole on your chosen position along the center line under the kick space...

Страница 5: ...k plate Use a 90 sweep elbow fitting to determine a cut mark on the other end of the pipe Then cut the pipe at the mark Slide the low voltage wires into the CanSweep clips as shown to complete the wir...

Страница 6: ...ening of the elbow will securely attach onto the spigot on the back of the CanSweep when it is time for connection Slide the CanSweep and low voltage wires into the opening on the baseboard Friction f...

Страница 7: ...ove the screw tightening the bag adapter and intake elbow junction Disassemble the bag adapter from the intake elbow and set aside with its screw and nut Allunits Disassemble the intake elbow from the...

Страница 8: ...ng bracket on the wall through upper and lower mounting holes Hang power unit onto wall mounting bracket Ensure the back brackets of the power unit are engaged with corresponding wall bracket fingers...

Страница 9: ...ric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet t...

Страница 10: ...ove the disposable bag release both latches on sides of the unit by pulling out and then pushing up Remove the pail from unit Grasp the edges of the bag collar and pull down The bag will slide off eas...

Страница 11: ...new one part no S10941416 Be sure to install it with the gasket on top as shown in illustration B at the botton of the page then snap in place the upper part of the top cap If need be reconnect the ex...

Страница 12: ...repeated several times should clear the obstruction If the blockage is not cleared contact your nearest Service Center Clean the interior or the unit and install a new permanent filter or disposable...

Страница 13: ...parts and repairs 4 11 7 13 KEY NO PART NO DESCRIPTION 550VF1 650VF1 700VF1 1 S10941410 700VF1 TOP CAP ASSEMBLY INCLUDING ITEM 5 UPPER PART 1 S10941412 550VF1 AND 650VF1 TOP CAP ASSEMBLY 1 1 2 S10941...

Страница 14: ...ons The duration of any implied warranty is limited to the period as specified for the express warranty VENMAR VENTILATION ULC S OBLIGATION TO REPAIR OR REPLACE AT VENMAR VENTILATION ULC S OPTION SHAL...

Отзывы: