Instructions for the installer, maintenance
technician and final user
46
© SandenVendo Europe SpA
7.2 Preventive Maintenance
In order to guarantee a good performance of the Vendor the following maintenance
operations are recommended:
Check the vending machine and its surroundings area, check for signs of rust on the
cabinet and obstructions of air vents
Open the door and check the absence of water accumulation, signs of rust, and
moisture around the edges of the door
Check the evaporator drain for obstructions (water in the evaporator area must drain
towards the condenser pan)
Periodically check the door seals. If damaged replace immediately
Periodically check that the condenser is clean
Check that the evaportor fans and the cooling unit run normally (the blades must be
free from any obstruction)
Check that the compressor and the condenser fans run normally ( the blades must be
free from any obstruction)
Check that all the selections are correctly delivered.