6
SM VI, 3157, 3158, 3159, P/N 4211051
Outlet Tester
An easy to read outlet tester can be obtained
from Vendnet (P/N 4211746) or any
electrical or electronic supply store.
Plug the tester into any grounded (3-prong)
115V AC outlet to detect faulty wiring. See
Figure 8.
Read the indicator lights as explained on the
tester. See Table 1 for explanation of faults.
Refer all indicated problems to a qualified
electrician.
CAUTION
Unplug all equipment on branch circuit before testing.
This is not a comprehensive diagnostic instrument.
Please refer to the tester
packaging for more information.
Table 1. Indicated Problems when using a tester
FAULT
REASON FOR FAULT
Open Ground
Ground contact not connected
Open Neutral
Neutral contact not connected
Open Hot
Hot contact not connected
Hot Ground Reverse
Hot and ground contacts interchanged
Hot Neutral Reverse
Hot and neutral contacts interchanged
Power Switch
Each vendor is equipped with a power
switch located on the power panel along
with a 3-Amp and a 5-Amp breaker. The
switch will shut-off the controller. See
Figure 9.
The 3-Amp breaker is protection for the
transformer.
The 5-Amp breaker is protection for the
entire vendor.
Figure 9. Power Switch, Breakers
Figure 8. 3-Prong Outlet Tester
A10593
NOTE
NOTE
NOTE
NOTE
A10733
POWER SWITCH &
BREAKERS
Содержание SM VI 3157
Страница 1: ...SEPTEMBER 2000 P N 4211051 Rev B Model 3157 3158 3159 Service Manual SNACK FOOD VENDOR SM VI...
Страница 14: ...12 SM VI 3157 3158 3159 P N 4211051 A10687 A10688...
Страница 44: ...42 SM VI 3157 3158 3159 P N 4211051 SCHEMATIC...
Страница 45: ...SM VI 3157 3158 3159 P N 4211051 43...
Страница 46: ...44 SM VI 3157 3158 3159 P N 4211051 KEYPAD OVERLAY...
Страница 47: ...SM VI 3157 3158 3159 P N 4211051 45...