background image

36   VELUX

ENGLISH

VELUX   37

ENGLISH

The products can be combined with most intelligent building installations 
(IBI). The IBI system must include an output module with one or more pro-
grammable outputs. When the outputs have been connected to the entries 
in the interface/repeater unit, the relevant products can be controlled via the 
interface/repeater unit. With two outputs, it is possible to control both of the 
functions    and   in an product or a group of products.

You can control up to 200 products or groups of products individually. Howe-
ver, individual control of a product or a product group requires one interface/
repeater unit per product or product group. If eg a group of skylights facing 
south and another group of skylights facing north are to be con-trolled 
individually by thermostats, the two groups must have an interface/repeater 
unit each. 

Intelligent building installations

Содержание KLF 100

Страница 1: ...VAS 452421 2010 03 KLF 100 ENGLISH User manual ESPA OL Manual de usario FRAN AIS Notice d utilisation JAPANESE...

Страница 2: ...2 VELUX VELUX 3 English User manual x x Espa ol Manual del usuario x x Fran ais Notice d utilisation x x Japanese User manual x x...

Страница 3: ...t function and connection 14 15 Settings Channels 16 19 Set channel 16 Block channel 17 Permanent blocking 18 19 Setting of position 20 21 Position UP 21 Position DOWN 21 System settings Register prod...

Страница 4: ...s The interface repeater unit can be used as a repeater that extends the operation range of remote controls in the system Product The interface repeater unit is used when products are to be controlled...

Страница 5: ...e disposed of in conformity with the relevant environmental regulations and ordinances The packaging can be disposed of with usual household waste Radio frequency band 2 4 GHz Radio frequency range 11...

Страница 6: ...is switched on After a short time menu item A is displayed A Language 1 Press to highlight your language Press Enter to confirm your choice 2 The display shows that the language has been saved After...

Страница 7: ...ucts described on pages 26 27 It is not necessary to go through the other submenus in menu item H The interface is now ready for use Thermostatic control of a VELUX skylight by a compa tible thermosta...

Страница 8: ...ire required CLOSE DOWN OFF is controlled by connecting C and 2 core wire required STOP is controlled by connecting C with both and 3 core wire required Note Alternatively a single contact can control...

Страница 9: ...ecommended to choose channel 7 1 Press to choose channel Press Enter to confirm your choice 2 The display shows that the chosen channel has been saved After a short time menu item D is displayed D Blo...

Страница 10: ...activating entry and entry from the external control device The blocking can also be cancelled temporarily by pressing Menu on the display of the interface The next time the entries are activated the...

Страница 11: ...ponds to the display information on a VELUX remote control This applies to all product types except Skylight You are therefore recommended to use the position table when setting the position Always ch...

Страница 12: ...efore proceeding H Registration from a remote control If you have a VELUX remote control you can copy the registered products from the remote control to the inter face repeater unit Note All products...

Страница 13: ...regis tration can take up to two minutes 4 The display shows that the new product s has have been registered Step 1 KLI 110 Transmit system from KLI by pressing the PRG button for 3 4 seconds LED flas...

Страница 14: ...our choice The display shows a list of all registered products 3 Press to highlight the product to be edited Press Edit to confirm that the product in question is to be edited 4 Press to highlight Sel...

Страница 15: ...to confirm your choice 2 Press to highlight Change Press Enter to confirm your choice The display now indicates that the security key has been changed 3 The display asks whether the security key of ot...

Страница 16: ...istered directly in the interface repeater unit as shown on page 23 they can be copied to other interface repeater unit or remote controls The copying takes place in 2 steps Step 2 must be completed w...

Страница 17: ...one and the same entry Each time the entry is activated the function will change For instance ordinary electric light in buildings is contro lled from a wall switch that turns the light both on and of...

Страница 18: ...confirm your choice 2 The display shows that the repeater function has been activated Press Continue to open for registration 3 The display shows that the repeater function is ready to be registered...

Страница 19: ...peater unit With two outputs it is possible to control both of the functions and in an product or a group of products You can control up to 200 products or groups of products individually Howe ver ind...

Страница 20: ......

Отзывы: