22
INSTALLATION
MANUAL
INSTALLATION
INSTALLATION OF THE THREE-PHASE METER SET
The THREE-PHASE METER SET is made up of two elements: a three-phase energy
meter and a smart gateway.
1. Select the circuit onto which you wish to install the THREE-PHASE METER SET.
At the meter outlet
In the home circuit
METER
Contracted
power
Electric
vehicle
power
ENERGY
METER
Home
power
PANEL
PANEL
Home
power
PANEL
PANEL
Electric
vehicle
power
ENERGY
METER
2. Install the three-phase energy meter and the smart gateway next to one another,
maintaining contact between the elements of each device that enable them to
communicate by means of infrared signals.
The three-phase energy meter and the smart gateway are designed for
installation on a DIN rail (DIN EN 60715).
3. Strip the power cables 10mm, and the neutral cable 8 mm.
4. Place the power and neutral cable contacts in the three-phase energy meter and
tighten the screws.
The incorrect or incomplete connection of voltage or other terminals can cause
malfunction of or damage to the device.
•
L1, L2, L3: Phase lines.
•
N: Neutral
METER
Contracted
power