2
EN
S A F E T Y
S E G U R I D A D
S Û R E T É
S E G U R A N Ç A
S I C H E R H E I T
READ AND SAVE THESE INSTRUCTIONS
•
Important Safety Instructions
WARNING – To Reduce The Risk Of Fire Or Electric Shock, Do Not
Use This Fan With Any Solid-State Speed Control Devise
• Installation Instructions
WARNING – To reduce the risk of fire, electric shock, or injury to
persons, observe the following:
• Installation work and electrical wiring must be done by qualified
person(s) in accordance with applicable codes and standards,
including fire-rated construction.
• When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
• Use this unit only in the manner intended by the manufacturer. If
you have questions, contact to the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag to the service panel.
! WARNING: MANUALS
This product has been designed to operate safely and reliable for
several years. However because of its electronic nature manuals
and technical information supplied along with the hand dryer must
be carefully read. Please keep this manual and the rest of
information for future consults. If you transfer the unit to a third
party please include manuals and unit technical information.
!! WARNING: ELECTRICAL CIRCUIT:
• This unit must be powered by a dedicated circuit branch
protected by a circuit breaker with the appropriate rating:
Model 240V:
Circuit Breaker: 16A
Model 120V:
Circuit Breaker: 20A
• Circuit cable must fit current consumption for your product as
stated in this manual.
• External electrical break circuits must be used in accordance with
local regulations of installation. The device must have a minimum
distance of 3mm between contacts in all poles, for disconnection.
• Minimum section of fixed wiring must be of 1,0 mm
SAFETY AND USE
• This unit has been designed for indoor use only, covered from
water sun and extreme temperatures do not use it outdoors or close
to moisture and heat generators.
• Minimal distance to water source must be at least 16 inches (40cm).
• Must be installed following the instructions of this manual.
• Manufacturer is not responsible for damages caused by misuses or
defective installations
• This hand dryer can only be revised maintained and repaired by
trained and authorized personnel.
• Always use original pieces and spare parts.
• Power the hand dryer from appropriate power source according to
the acquired equipment. The unit electrical specifications plate
shows the power rating.
• This device is not intended to be used by persons (children
included) having reduced capabilities (physical, sensory, mental), or
lack of experience and knowledge exception made of those who
have had supervision and training on the use of the device by a
person responsible for its security. Children should be always
supervised to avoid them playing with the device.
• This product is designed for an efficient and quick hand drying.
Never try to dry any other part of the body
DISPOSAL
Packaging:
Packaging protects the unit in warehouse and
transportation. It is made of recyclable
materials. When packaging is no longer
needed, dispose it appropriately according to
recycling normative.
When replacing a product:
This unit has been marked with European WEEE symbol. Obsolete
or inoperative units must be disposed according to electric and
electronic waste management normative in your country. This unit
must be disposed in an appropriate manner to avoid potential
environmental damages or just for re-cycling some of their
materials. In Europe you must dispose this unit in a recycling centre
in your area or contacting your dealer or local government.
MAINTENANCE
• External: This unit must be cleaned once per day using a soft cloth
with water for removing dust and water over external case. Do not
use scouring agents or all purpose cleaners. Never immerse unit in
water.
• Water Tank: Water from drying process is recollected in a tank
located in bottom part of the unit. Water tank must be emptied at
least once per week. This unit generates a visual and audible alarm
when tank is near high level. If tank is not emptied water will
overflow dropping to the floor. This unit works properly even when
WARNING:
PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING AND SWITCHING ON
• Foreign objects must not be put neither in nor over the hand dryer
• Heavy objects must not be put over the hand dryer
• If this unit fails it must be taken out of order and technical service
(or distributor) must be called for a product check.
• Inner space of this product is protected and locked by screws so
only trained and authorized per-sonnel should revise this unit.
There are neither serviceable nor replaceable parts inside the unit.
high level alarm is in ON status.
• Dust Filters: This unit has 2 dust filters (one per motor) located in
water tank. This filters need to be revised and cleaned at least once
per week. Please consult maintenance section of this manual before
performing any maintenance operation.
INSTALLATION AND OPERATION
Revise related sections of this manual.
7