Velbus manual VMB1DM – edition 1 – rev.1.0
3
Features::
◊
Fit for light bulbs, halogen on mains and low-mains halogen in combination with a dimmable electronic
transformer.
◊
Phase cut-off technology for resistive (light bulbs) and capacitive (dimmable electronic transformers) loads.
◊
Phase cut-off technology for inductive loads (dimmable wound transformers).
◊
Noiseless through CoolMOSIM FET.
◊
Mains pollution (EMI) conform EN55015
◊
Required mains voltage: 100-125V/60Hz of 220-240V/50Hz
◊
Maximum load: 300W @ 230V or 150W @ 115V
◊
Built-in non-resettable fuse
◊
Gradual switch on or off (ca. 1.5s) will prolong the lamp’s life
◊
Dimming from 0 to 100% in ca. 4 seconds
◊
Manual control on the module
◊
LED indicators for:
•
The operation modes (slow, fast, very fast or 2 x blinking and continuously ON)
•
The power voltage
•
Data reception and forwarding through VELBUS
◊
9 different operation modes (adjustable through ‘mode’ rotary switch):
•
Moment control
•
Start/stop timer
•
Staircase lighting timer
•
Dimmer
•
Dimmer with memory function
•
Multi-position dimmer
•
Slow-on dimmer
•
Slow-off dimmer
•
Slow on-off dimmer
◊
16 possible time set-ups (adjustable through hexadecimal rotary switch): moment - 5s - 10s - 15s - 30s -
1min -
2 min - 5min - 10min - 15min - 30min - 1u - 2u - 5u - 1dag - on/off
◊
Controllable by connecting several push buttons in parallel.
◊
Push button input debounce: 65ms.
◊
Control through VELBUS.
◊
Programmable without PC.
◊
Easy learning process by operating the desired push buttons in the learning mode.
◊
7 different control possibilities:
•
Using push buttons turning on the lamp to full intensity.
•
Using push buttons turning the lamp off.
•
Using push buttons turning on the lamp to full intensity or turning off the lamp
•
Using push buttons activating the set operation mode.
•
Using push buttons increasing the lamp’s light intensity
•
Using push buttons decreasing the lamp’s light intensity
•
Using push buttons creating atmospheric lighting.
•
Using push buttons turning on the lamp on the desired intensity.
◊
Memory for 14 different push buttons/sliders per command.
◊
Learned push buttons are saved ion case of a power failure.
◊
Report to control modules for modifying the LED status.
◊
247 possible addresses (adjustable through ‘ADDR’ rotary switch)
◊
Required mains voltage: 12 ... 18VDC
◊
Consumption in standby: 35mA at 18V (15mA at 16V).
◊
Consumption activated relay: 50mA at 18V (30mA at 16VDC)
◊
Standard DIN-rail housing (2 modules)
◊
Dimensions (L x W x H): 90 x 36 x 58mm.
◊
Weight : 95g