Operation: 

 
The dimmer module can be operated in different ways:  
 

  Using push buttons connected to the direct push button input: 

o

  activating the set mode on the module.. 

  Using push buttons connected to the Velbus through a push button interface or control module: 

o

  turning on the lamp to full intensity. 

o

  switching off the lamp. 

o

  turning on the lamp to full intensity or turning off the lamp. 

o

  activating the set operation mode. The mode and time setting will influence the dimmer module 

only when using these push buttons (see operation mode and time setting table).  

o

  increasing the lamp’s intensity. 

̇

 

A short press will turn on the lamp to full intensity (a short press with the dimmer with 
memory function will, in case the lamp is off, turn on the lamp at the intensity which was 
last used).  

̇

 

A long press will increase the lamp’s intensity until the push button is released. 

o

  decreasing the lamp’s intensity. 

̇

 

A short press will immediately switch off the lamp. 

̇

 

A long press will decrease the lamp’s intensity until the push button is released. 

o

  turning on the lamp to a specific light intensity (atmosphere). 

o

  using sliders turning on the lamp to the desired intensity 

 
LED indication: 

 

The control module LEDs and the operation mode LED on the dimmer module indicate the status of the dimmer: 

  The LED will burn if the lamp does not light up. 

  The LED will burn if the lamp burns at a stable light intensity.   

  The LED blinks rapidly as long as the lamp’s light intensity is modifying.  

  The LED blinks slowly when the switch-off delay is running.  

  The LED blinks very rapidly if the dimmer module is set in learning mode. 

 

Learning mode: 

 

Only push buttons connected to the Velbus via a push button interface or a control panel are appropriate for the 
procedure below. Each command can accept up to 14 different push buttons. Memorize he unique address of the 
module. 
 

Address  Command 

F1 

OFF: Learning push buttons switching off the lamp 

E1 

ON: Learning push buttons turning on the lamp to full intensity 

D1 

TGL: Learning push buttons turning on the lamp to full intensity or turning the lamp off 

C1 

DIM: Learning push buttons/sliders activating the set mode on the module 

B1 

UP: Learning push buttons increasing the lamp’s intensity 

A1 

DWN: Learning push buttons decreasing the lamp’s intensity 

91 

ATM: Learning push buttons turning on the lamp to a specific light intensity (atmosphere) 

81 

ADM: Lamp’s light intensity for corresponding atmosphere push buttons 

 
The lamp will be switched off and the operation mode LED will blink very rapidly to indicate the learning mode. 
The LEDs of the learned push buttons will also blink very rapidly. In this way it is possible to see which push 
buttons for the corresponding group have already been learned. You can add a specific push button by 
maintaining it pressed until the lamp lights up. When releasing the push button the lamp will switch off and the 
push button indication LED will blink very rapidly as a confirmation. If this does not work then the maximum 
amount of push buttons has been reached. To delete a learned push button, maintain it pressed. When releasing 
the push button the indication LED will be turned off. You can delete all learned push buttons for a specific control 
group by maintaining the manual control on the dimmer module pressed until the lamp lights up. When releasing 
the manual control push button the lamp and the indication LEDs of all corresponding push buttons will turn off. 
 
To learn a light atmosphere set the dimmer module on address ‘81’. The LEDs of the push buttons creating 
atmospheric light will blink rapidly. To assign a specific light intensity to an atmosphere push button, operate the 
corresponding push button until the desired light intensity has been reached. 
 
To set all learned atmospheric setting to full intensity, maintain the manual control on the dimmer module pressed 
until the lamp burns at full intensity. When releasing the manual control push button the lamp and the indication 
LEDs of all corresponding push buttons will turn off.  

Содержание VMB1DM

Страница 1: ...Velbus manual VMB1DM edition 1 rev 1 0 1 VMB1DM Dimmer Module for Velbus system ...

Страница 2: ...transformer capacitive load 5 Use with low mains halogen through a wound transformer inductive load 6 Troubleshooting 6 Low voltage connection 7 Direct control using several push buttons 7 Control via VELBUS system 8 Combination of direct push buttons and VELBUS control 9 Connection 10 Termination 10 Addressing 11 Time setting 11 Operation mode 12 Operation 13 LED indication 13 Learning mode 13 ...

Страница 3: ...table through hexadecimal rotary switch moment 5s 10s 15s 30s 1min 2 min 5min 10min 15min 30min 1u 2u 5u 1dag on off Controllable by connecting several push buttons in parallel Push button input debounce 65ms Control through VELBUS Programmable without PC Easy learning process by operating the desired push buttons in the learning mode 7 different control possibilities Using push buttons turning on...

Страница 4: ...ms 1s 2s of 3s which can be saved in the non volatile memory The module can react to push button messages sent over the VELBUS A modification of the dim status will be reported on the VELBUS When modifying the dim status the module will send instructions to adjust the status of the LEDs on the control modules Instructions will be accepted when calling up the module type module name module status r...

Страница 5: ... electronic transformer capacitive load L H PB BUS VMB1DM 12V L N230 N115 LOAD N L 115V AC POWER MODE TIME ADDR 12VAC PRIM electronic transformer Dimmable 1 5mm2 1 5mm2 0 5mm2 1 5mm2 L H PB BUS VMB1DM 12V L N230 N115 LOAD N L 230V AC POWER MODE TIME ADDR 12VAC PRIM electronic transformer Dimmable 1 5mm 2 1 5mm2 0 5mm2 1 5mm2 Opgelet Place the MODE rotary switch on one of the following positions 0 ...

Страница 6: ... E or F The electronic transformer must be short circuit and thermal protected Make sure to always connect a lamp on the transformer an unloaded transformer has an inductive behavior and could damage the dimmer This dimmer is not suited for toroidal transformers Troubleshooting The dimmer module features a non resettable fuse which will melt in case of a short circuit or overload In this case retu...

Страница 7: ... button input by using the VELBUS or a combination of both possibilities Direct control using several push buttons L H PB BUS VMB1DM 12V L N230 N115 LOAD N L 230V AC POWER MODE TIME ADDR 1 5mm2 1 5mm2 0 5mm2 12V SUPPLY PUSH BUTTONS 1 5mm2 Remark Position the address on 00 to switch off the communication with the VELBUS Also erase all learnt push buttons In the other case de dimmer module will caus...

Страница 8: ...30 N115 LOAD N L 230V AC POWER MODE TIME ADDR 1 5mm2 1 5mm2 0 5mm2 12V SUPPLY L H 0 5mm PAIR TWISTED BUS 2 1 5mm2 Remark For connection between the modules use twisted pair cable ex EIB 2x2x0 8mm2 UTP 8x0 51mm CAT5 or other Use minimum 0 5mm cable Connect the bus mind the polarity to the module ...

Страница 9: ...2V L N230 N115 LOAD N L 230V AC POWER MODE TIME ADDR 1 5mm2 1 5mm2 0 5mm2 12V SUPPLY PUSH BUTTONS L H 0 5mm PAIR TWISTED BUS 2 1 5mm2 Remark For connection between the modules use twisted pair cable ex EIB 2x2x0 8mm2 UTP 8x0 51mm CAT5 or other Use minimum 0 5mm cable Connect the bus mind the polarity to the module ...

Страница 10: ...the TERM jumper Remove the jumper in all other cases Remark If different cable wiring topologies tree star loop are used place a jumper on the end module of the longest cable only NOT on each end point MODE TIME ADDR TERM VELBUS Direct push button control 12V supply Manual control Termination Operation mode LED 230VAC N Forwarding LED Reception LED Power LED Address setting Operation mode Time set...

Страница 11: ...mer or 10s dimming speed in slow on off dimmer mode 3 15 timer or 15s dimming speed in slow on off dimmer mode 4 30s timer or 30s dimming speed in slow on off dimmer mode 5 1min timer or 1min dimming speed in slow on off dimmer mode 6 2min timer or 2min dimming speed in slow on off dimmer mode 7 5min timer or 5min dimming speed in slow on off dimmer mode 8 10min timer or 10min dimming speed in slo...

Страница 12: ...happened more than 5 seconds ago the lamp will turn off After the set time see TIME rotary switch has elapsed the lamp will turn off 5 or D Slow on dimmer Operating the push button will turn on the lamp gradually The time needed for the lamp to burn at full intensity depends on the rotating switch used to determine the time setting see TIME rotary switch Operating the push button while the lamp is...

Страница 13: ...sh buttons switching off the lamp E1 ON Learning push buttons turning on the lamp to full intensity D1 TGL Learning push buttons turning on the lamp to full intensity or turning the lamp off C1 DIM Learning push buttons sliders activating the set mode on the module B1 UP Learning push buttons increasing the lamp s intensity A1 DWN Learning push buttons decreasing the lamp s intensity 91 ATM Learni...

Страница 14: ...earning mode by resetting the dimmer module s original address When using firmware version 0735 you will be able to delete all push buttons and sliders saved into the memory of the dimmer module at once Set the address to one of the learning addresses Maintain the manual control on the dimmer module pressed for 10 seconds The relay will activate and deactivate again after 7 seconds to confirm the ...

Страница 15: ...Velbus manual VMB1DM edition 1 rev 1 0 15 ...