Win O2 FLS 2000 Скачать руководство пользователя страница 1

Operating instructions

FLS 2000

FLS: 
The intelligent,  
natural  
window ventilation 
system

Содержание FLS 2000

Страница 1: ...Operating instructions FLS 2000 FLS The intelligent natural window ventilation system...

Страница 2: ......

Страница 3: ...Version 2 0 FLS 2000 Operating Instructions...

Страница 4: ...Open window green Activate Day programme Switch off programme window closes no programme active Switch off system remote control unit switched off Switch on system 3s OPENING CLOSING possible without...

Страница 5: ...for three seconds until the display reacts What does the display mean State Week programme Day programme lights up Week programme active flashes Day programme active off Programme off only FLS 2000 au...

Страница 6: ...he system 9 4 2 Selecting the week programme 9 4 3 Changing the ventilation programme 10 4 4 Switching off the ventilation programme 10 4 5 Manual opening of the window 11 4 6 Manual closing of the wi...

Страница 7: ...operated or touched if its housing is defective and it must not come into contact with water either The window is opened and closed slowly It is nevertheless important to make sure that nothing can be...

Страница 8: ...cted to a weather sensor C The window ventilation system can also be operated with a manual switch D and a remote control unit E1 E2 A plug in power supply F or a flush mounted power supply unit suppl...

Страница 9: ...be set to dark when the FLS 2000 automatic system is configured The status display consists of a red and a green LED The following displays can appear The weather sensor C is mounted on the outside of...

Страница 10: ...ommands can be conveniently sent from a workplace or chair with the remote control unit E1 E2 This can also be used to select the ventilation programmes week programme and day programme of the automat...

Страница 11: ...een the inside and outside temperature If the threshold values specified in the system are exceeded because the ventilation creates too much draught the wind blows too strongly or the inside or outsid...

Страница 12: ...ays considered however unless you want to force the window to open see chapter 4 5 It is also possible to open the window completely see chapter 5 If the FLS window ventilation system ventilates too m...

Страница 13: ...mote control unit Please note that the remote control unit may also be blocked in the newly selected programme If you would like a different configuration for the week or day programme please contact...

Страница 14: ...ing the red and green LED for a short time It subsequently returns to the last state that was selected Point your remote control unit in the direction of the window actuator and press the Week button...

Страница 15: ...o not want the FLS 2000 automatic system to execute a ventilation programme then switch the ventilation programme off To do this press the Programme off button of your remote control unit The window w...

Страница 16: ...nd will override the programme for a defined period of time manual operation time You can double or triple the manual ope ration time by pressing the Open button several times up to 3x Safety is still...

Страница 17: ...nd do not want any ventilation during this time for example then press both buttons on the manual switch for 3 seconds In this state the system is completely switched off and does not react any more t...

Страница 18: ...ow moves to the release position When both LEDs alternately flash red and green the window is unlocked Now pull the release lever 2 on the linkage holder all the way down The window can now be complet...

Страница 19: ...Make sure that the linkage sits correctly in the holder You might have to pull the release lever further up a little if a red area is still visible at the top of the holder Next press the service butt...

Страница 20: ...ek programme is active the window is currently in an opened state Day programme is active the window is currently in a closed state Day programme is active the window is currently in an opened state S...

Страница 21: ...indow unlocking see chapter 5 The FLS is in an unlocked state Error see chapter 7 Blockage during closing Blockage during opening A different signalisation is possible when an FLS is overridden if man...

Страница 22: ...locking push the window shut when both LEDs are alternately flashing fit the linkage correctly in the holder and press the service button for 3 seconds until the display reacts Blockage while opening...

Страница 23: ...mechanism If the turning fitting becomes more sluggish or the window becomes distorted over time this can block the mechanism of the FLS As a preventive measure please observe the instructions for gr...

Страница 24: ...ned with a moist cloth soaked in soapy water The weather sensor can be cleaned in the same way as the window actuator It must not be subjected to any knocks however Avoid scraping and scratching it as...

Страница 25: ...Your serivce partner Pdf October 2013...

Отзывы: