background image

HAM06WS 

18.04.2017 

©

Velleman nv 

10

Remarks: 

o

 

The alarm station only remembers the last added wireless sensor added to a zone! This means that per 
zone, only one wireless PIR sensor can be used. 

o

 

The red LED will blink when the battery is almost drained (<7V). 

o

 

Do not install the sensor onto a metal support or plate. 

o

 

Keep the sensor away from direct sunlight and temperature variations (air conditioner, heating...). 

10.

 

Door or window Sensor 

Install the 2 sensors as illustrated on page 

2

 of this manual. 

 

Make sure to align the triangles on both sensors and to keep the spacing between them less than 5mm. 

 

Open the battery compartment and install the included 12V battery. Assign the sensor with a unique address 
with the DIP switches. Close the sensor and program it into the central unit. The red LED on the sensor will 
light at each door opening.  

Remark: The transmitter will emit a sound when opening the battery compartment 

11.

 

Technical specifications 

Central Unit 

Power Supply 

12VDC (incl.) 

Standby Power 

12VDC (incl.) 

Working Frequency 

433Mhz 

Remote Control Range 

± 30m 

Static Current 

150mA 

Alarm Volume 

> 90dB 

PIR Sensor 

Detection Angle 

110° 

Detection Distance 

max. 12m 

Power Supply 

9VDC (order code 

6LR61

, not incl.) 

Static Current 

30μA 

4-Key Remote Control 

Power Supply 

3VDC (order code 

CR2032

 button cell, incl.) 

Panic Button 

Power Supply 

12VDC (order code 

GP23GA

, incl.) 

Door Contact 

Power Supply 

12VDC (order code 

GP23GA

, incl.) 

Siren 

Power Supply 

12VDC 

Current 

< 800mA 

Use this device with original accessories only. Velleman nv cannot be held responsible in the event 
of damage or injury resulted from (incorrect) use of this device. 

The information in this manual is subject to change without prior notice. 

© 

COPYRIGHT NOTICE

 

The copyright to this manual is owned by Velleman nv.

 All worldwide rights reserved.  

No part of this manual or may be copied, reproduced, translated or reduced to any electronic medium or otherwise without 
the prior written consent of the copyright holder.  

 

 

Содержание HAM06WS

Страница 1: ...MSYSTEEM SYST ME D ALARME SANS FIL SISTEMA DE ALARMA INAL MBRICO DRAHTLOSES ALARMSYSTEM SISTEMA DE ALARME SEM FIOS USER MANUAL 3 GEBRUIKERSHANDLEIDING 11 NOTICE D EMPLOI 19 MANUAL DEL USUARIO 27 BEDIE...

Страница 2: ...HAM06WS Rev 04 18 04 2017 Velleman nv 2 1 2 3...

Страница 3: ...ching live wires can cause life threatening electroshocks Remove power before opening the cover 3 General Guidelines Refer to the Velleman Service and Quality Warranty on the last pages of this manual...

Страница 4: ...se signals to the central unit 7 Alarm Unit a Layout Refer to the illustration on page 2 of this manual A MEDICAL push to trigger the medical alarm B FIRE push to trigger the fire alarm C HELP push to...

Страница 5: ...system is in DISARM mode e Entering the programming mode To enter the programming mode put the central unit in DISARM mode first and press the SET button The message INPUT LEVEL will be displayed Ente...

Страница 6: ...Report 1 Arm report 2 No report Arm report A report is sent to the central unit No report No report is sent to the central unit Submenu 4 Delay This menu will be used to program the time needed for th...

Страница 7: ...display 3 message types 1 Smoke 2 Gas 3 Panic 1 Smoke smoke alarm 2 Gas gas alarm 3 Panic panic alarm Bypass The alarm zone has been deactivated Setup Menu This Setup menu has following submenus 1 Ale...

Страница 8: ...ax value is 8 rings Enter a number from 01 to 99 and confirm with the button Input ring times Note unfortunately there is no direct relationship between the entered number and the number of rings E g...

Страница 9: ...3 AWAY ARM entering the AWAY mode R4 HELP panic function activation push upwards to activate Remark Follow these steps to assign a different code when 2 or more remote controls have been encoded simil...

Страница 10: ...ound when opening the battery compartment 11 Technical specifications Central Unit Power Supply 12VDC incl Standby Power 12VDC incl Working Frequency 433Mhz Remote Control Range 30m Static Current 150...

Страница 11: ...el tegen regen vochtigheid en opspattende vloeistoffen Elektrocutiegevaar bij het openen van het toestel Schakel de voeding uit alvorens de behuizing te openen Raak geen kabels aan die onder stroom st...

Страница 12: ...Belangrijke opmerking voor blokken 5 tot en met 8 Verbind ieder blok dat men niet gebruikt steeds door met de massa blok 2 of blok 3 om de centrale geen valse signalen te geven 7 Alarmcentrale a Over...

Страница 13: ...n ten behoeve van brand gas of paniekdetectie 24h functie zijn steeds actief ook wanneer het systeem in DISARM status staat e De centrale in programmeermodus plaatsen Om de centrale in programmeermodu...

Страница 14: ...enu is voor toekomstige uitbreiding van de software en heeft geen functie Submenu 3 Report 1 Arm report 2 No report Arm report Rapport naar de centrale No report Geen rapport naar de centrale Submenu...

Страница 15: ...ij brand gaslek of paniek Het alarm wordt dus ook geactiveerd wanneer het systeem in DISARMED modus staat Dit wordt bijvoorbeeld gebruikt bij het aansluiten van een brandsensor Men kan 3 verschillende...

Страница 16: ...n aangesloten op de centrale moet overgaan om over te schakelen naar de besturingsfunctie op afstand zie verder De defaultwaarde en max is 8 keer Voer een getal in van 01 99 en bevestig met de toets I...

Страница 17: ...om het toestel in DISARM modus te plaatsen 3 om te luisteren naar de ingebouwde microfoon van de centrale 4 om af te bellen 8 Toetsen op de afstandbediening en het hulpalarm Raadpleeg de figuren op p...