CAMSET7 & 8
VELLEMAN
2
3. Operation
a) Operation of the Camera (outdoors)
•
The bell inside the house is activated when the bell button is pressed
•
The microphone makes communication possible
•
Nightly visitors are displayed clearly thanks to the device's integrated light source.
b) Operation of the Central Unit (indoors)
This is what happens when you have a visitor:
•
The central unit produces a ringing sound, the visitor is displayed on the screen and can also be heard.
•
If you want to receive the visitor, you can pick up the receiver and press the key for the door opener (4 in fig. 2 on
page 1).
•
If you do not want the visitor to know you are in, you can leave the receiver in the cradle and press the monitoring
button. You should now be able to see and hear the visitor for 30 seconds before the display deactivates.
•
The contrast and the volume can be adjusted with keys 5 & 6 (fig. 2), respectively.
•
Pick up the receiver and press the button (n°4 in fig. 2) to activate the door opener.
4. Installation
a) Installation of the Camera
Mount the outdoor section on a wall at eye level. Connect the camera with the central unit. You should now be able
to execute an operation test.
b) Installation of the Central Unit
Use the included screws and plugs to mount the metal plate on a wall at eye level. Wire the central unit and fix the
unit on the metal plate.
c) Connecting a Spare Camera (CAM14 & CAM15)
Use the
CAM14
with the
CAMSET7
and the
CAM15
with the
CAMSET8
.
5. Safety Instructions
•
Do not open the device yourself as this may expose you to electroshocks.
•
Mount the device in a well-ventilated location and protect it against moisture, dust and direct sunlight.
•
Do not use chemicals on the device for cleaning purposes; use a clean & dry cloth instead.
•
Do not press the monitoring key (2 in fig. 2, page 1) for too long.
•
Never press multiple buttons simultaneously.
•
Do not hold the door-opening key (4 in fig. 2, page 1) any longer than 5 seconds.
6. Specifications
Input Signal
standard PAL signal, VS 0.5-1.4Vp-p
Input Impedance
75
Ω
Video Signal Bandwidth
5.5MHz
Picture Resolution
horizontal
≥
380 TV lines
Shutdown Delay of Display
30 seconds
Night Illumination Source
IR (only B/W camera for CAMSET7)
Lens Angle
92°
Power Consumption
2W in standby, 15W in operation
Dimensions of Central Unit
186 x 222 x 55mm (width x depth x height)
Total Weight
1.6kg (camera included)