background image

In view of the constant evolution in standards and design, the characteristics of the elements contained in this manual are subject 

to change without prior notice. These characteristics, as well as the availability of components, are subject to confirmation by 

Ormazabal

.

CAUTION! 

When medium-voltage equipment is operating, certain components are live, other parts may be in movement and some may 

reach high temperatures. Therefore, the use of this equipment poses electrical, mechanical and thermal risks.
In order to ensure an acceptable level of protection for people and property, and in compliance with applicable environmental 

recommendations, 

Ormazabal

 designs and manufactures its products according to the principle of integrated safety, based on 

the following criteria:

 • Elimination of hazards wherever possible.
 • Where elimination of hazards is neither technically nor economically feasible, appropriate protection functions are 

incorporated in the equipment.

 • Communication about remaining risks to facilitate the design of operating procedures which prevent such risks, 

training for the personnel in charge of the equipment, and the use of suitable personal protective equipment.

 • Use of recyclable materials and establishment of procedures for the disposal of equipment and components so 

that once the end of their service lives is reached, they are duly processed in accordance, as far as possible, with the 

environmental restrictions established by the competent authorities.

Consequently, the equipment to which the present manual refers complies with the requirements of section 11.2 of Standard 

IEC 62271-1. It must therefore only be operated by appropriately qualified and supervised personnel, in accordance with the 

requirements of standard EN 50110-1 on the safety of electrical installations and standard EN 50110-2 on activities in or near 

electrical installations. Personnel must be fully familiar with the instructions and warnings contained in this manual and in other 

recommendations of a more general nature which are applicable to the situation according to current legislation

[1]

.

The above must be carefully observed, as the correct and safe operation of this equipment depends not only on its design but also 

on general circumstances which are in general beyond the control and responsibility of the manufacturer. More specifically:

 • The equipment must be handled and transported appropriately from the factory to the place of installation.
 • All intermediate storage should occur in conditions which do not alter or damage the characteristics of the equipment 

or its essential components.

 • Service conditions must be compatible with the equipment rating.
 • The equipment must be operated strictly in accordance with the instructions given in the manual, and the applicable 

operating and safety principles must be clearly understood.

 • Maintenance should be performed properly, taking into account the actual service and environmental conditions in 

the place of installation.

The manufacturer declines all liability for any significant indirect damages resulting from violation of the guarantee, under any 

jurisdiction, including loss of income, stoppages and costs resulting from repair or replacement of parts.

Warranty

The manufacturer guarantees this product against any defect in materials and operation during the contractual period. In the 

event that defects are detected, the manufacturer may opt either to repair or replace the equipment. Improper handling of this 

equipment and its repair by the user shall constitute a violation of the guarantee.

Registered Trademarks and Copyrights

All registered trademarks cited in this document are the property of their respective owners. The intellectual property of this manual 

belongs to 

Ormazabal

.

[1] 

For example, in Spain the “Regulation on technical conditions and guarantees for safety in high-voltage electrical installations” – Royal Decree 

337/2014 is obligatory.

Содержание ORMAZABAL ekor.rtk

Страница 1: ...LIB ekor rtk Setting and assembly of the voltage detection unit General instructions IG 094 EN version 09 01 08 2019...

Страница 2: ...ectrical installations Personnel must be fully familiar with the instructions and warnings contained in this manual and in other recommendations of a more general nature which are applicable to the si...

Страница 3: ...um L1 L2 L3 8 3 Technical specifications 9 3 1 Rated values 9 3 2 Mechanical design 9 3 3 Insulation tests 9 3 4 Electromagnetic compatibility 10 3 5 Climatic tests 10 3 6 Mechanical tests 10 4 Voltag...

Страница 4: ...entional medium voltage line coupling systems such as voltage transformers are not required as it takes this signal directly from the capacitor dividers installed in the bushings The ekor rtk unit is...

Страница 5: ...This calculate the r m s value of each voltage and compares it with certain pre defined values to determine whether the voltage is above or below the set threshold Where the voltage is above the volt...

Страница 6: ...ekor rtk The lack of external power to the relay means that all output contacts are OFF The following table shows the statuses of the output contacts and an explanation of their indication Output con...

Страница 7: ...2 4 1 Independent Logic With this type of logic the unit provides a contact that indicates the absence and or presence of voltage for each phase The terminals to be accessed to obtain the information...

Страница 8: ...als J1 6 J1 7 Figure 2 4 Terminals 2 4 3 Voltage absence OR Logic Sum L1 L2 L3 With OR logic the unit terminal block provides the information on the absence of voltage in the event of a lack of voltag...

Страница 9: ...Temperature Operation 40 C 60 C Storage 40 C 70 C 3 2 Mechanical design IP rating Case IP47 Terminals IP2X In cubicle IP3X Dimensions See attached diagram 100 x 180 x 40 mm Weight 0 3 kg Connection Ca...

Страница 10: ...00 4 12 Sinusoidal damped wave 2 kV 1 kV EN 50081 2 55011 Radiated emissions Group 1 150 kHz 30 MHz Class A 3 5 Climatic tests IEC 60068 2 1 Slow changes Cold 40 C 960 min IEC 60068 2 2 Slow changes H...

Страница 11: ...on the type of cubicle in which it is installed 1 Relay ekor rtk 2 Wiring from bushing to ekor rtk relay 3 Wiring from ekor rtk relay to ekor vpis 4 Support for ekor rtk relay in cgmcosmos l feeder cu...

Страница 12: ...ting status 1 Test push button 2 Indication LED Figure 4 3 Test push button and indication LED 4 3 ekor rtk relay installation To install an ekor rtk relay in a cubicle you must have the ekor rtk volt...

Страница 13: ...the cable supplied in the kit to the relay and to the indicator Figure 4 7 Connect the relay to the display using the supplied cable 5 Connect the terminations running from the ekor rtk relay to the...

Страница 14: ...Figure 4 10 ekor rtk in cubicles cgmcosmos v R AV 4 3 3 Feeder cubicles cgmcosmos l In cgmcosmos l feeder cubicles the ekor rtk relay is located below the manometer to the left of the ekor vpis voltag...

Страница 15: ...lay is located at the bottom right below the ekor vpis voltage presence indicator Figure 4 12 ekor rtk in cubicles cgm 3 l IG 094 EN version 09 01 08 2019 15 General instructions ekor rtk Setting and...

Страница 16: ...SW3 defines the actuation time and SW4 specifies the line frequency The possible configurations obtained using selector S1 are those shown below depending on the system to which the cubicle where the...

Страница 17: ...50 Hz ON X cgmcosmos system cubicles with voltage presence indication from the ormalink connecting set SW1 SW2 Voltage SW3 Time SW4 Frequency OFF X X 3 5 36 kV 100 ms X 50 Hz ON X cgm 3 system cubicl...

Страница 18: ...icator ekor vpis E Output contacts F Power supply G Test push button W0 Error output Figure 5 1 Connection diagram of relay ekor rtk IG 094 EN version 09 01 08 2019 18 Connection diagram General instr...

Страница 19: ...s cgm 3 and diagram 996414 for cubicles cgmcosmos which are included with the unit A Power supply S l1 L1 output S l2 L2 output S l3 L3 output B Bushing cgm W0 Error output Figure 6 1 Connection diagr...

Страница 20: ...7 Dimensions Figure 7 1 Dimensions in mm for relay ekor rtk IG 094 EN version 09 01 08 2019 20 Dimensions General instructions ekor rtk Setting and assembly of the voltage detection unit...

Страница 21: ...General instructions ekor rtk Setting and assembly of the voltage detection unit Notes Notes IG 094 EN version 09 01 08 2019 21...

Страница 22: ...Notes General instructions ekor rtk Setting and assembly of the voltage detection unit Notes IG 094 EN version 09 01 08 2019 22...

Страница 23: ......

Страница 24: ...Subject to change without prior notice For further infotmation contact Ormazabal www ormazabal com Ormazabal Protection Automation IGORRE Spain...

Отзывы: