Defects, Cause, Elimination
14.02.11
BRI-7570_020
53
Defect
Cause
Elimination
Suction with fan (op-
tion) does not work
Motor protection switch Q1
has triggered
Find fault and clear, acti-
vate motor protection switch
Rated current setting incor-
rect
Check, reset if necessary
Contactor K2 defective
Check and replace if nec-
essary
Process control SA12
defekt
Check and replace if nec-
essary
Pedal S11 defective
Check and replace if nec-
essary
Fan motor defective
Check and replace if nec-
essary
No vacuum
Check central suction at
customer’s
Suction lower buck
with connection to
central suction (op-
tion)
Process control SA12
defective
Check and replace if nec-
essary
Pedal S11 defective
Check and replace if nec-
essary
5/2 directional control valve
Y7 defective
Check and replace if nec-
essary
Suction valve Z3 defective
Check and replace if nec-
essary