Veilux VRHD-8-4SDI Operating Instruction & User’s
11
Guide
www.Veilux.net
[Figure 2-3. Terminal Block Description]
4) PTZ Camera/Keyboard Controller
Connect PTZ camera to TRX+(No.4) and TRX-(No.5) and GND(No.10). You may refer to APPENDIX for
supported PTZ camera list in this manual. Keyboard Controller has same connection way of PTZ camera.
PTZ Camera may not be working properly if GND is not connected.
5) Sensor/Relay
Connect Sensor/Relay to Terminal Block directly.
(1) Sensor Connection
①
Connect Sensors to the Terminal Block S1 ~ S4.
②
Each input terminal may be connected regardless of the channel number.
Sensor has the type of NC(Normal Close) and NO(Normal Open).
For Setup {Menu}
{Setup}
{Action}
{Event}
{Sensor Type}
NC(Normal Close)
: Normally closed; opens when a signal is received.
NO(Normal Open)
: Normally opened: closed when a signal is received.
(2) Relay Connection
①
Outputs alarm signals to external devices such as siren by relaying them to these external devices.
②
Connect Relay to R1 of Terminal Block (TB1).
Relay has the type of NC(Normal Close) and NO(Normal Open).
For Setup
{Menu}
{Setup}
{Action}
{Alarm}
{Relay Type}
NC(Normal Close)
: Normally closed; opens when a signal is received.
NO(Normal Open)
: Normally opened: closed when a signal is received.
Chapter 3. Operation and Setup Tools
1
-
6
-
3
SH2 series Front Panel Button
No.
Name
Feature
1
POWER
Power On/Off
2
MOVE & DISPLAY
Move from one category to another or change the display
mode
3
ESC
Exit the current menu or selects the upper menu
4
MENU
Various Modes
Содержание VRHD-8-4SDI