![Veichi SI10 Скачать руководство пользователя страница 37](http://html2.mh-extra.com/html/veichi/si10/si10_manual_3835939037.webp)
Solar Pump Controller Manual
36
H-68 Data
format
0:non verifying (N ,8 ,1)
1:even verifying (E ,8 ,1)
2: odd verifying (O ,8 ,1)
3:non verifying (N ,8 ,2)
3
〇
344H
H-69 Baud
rate
0:1200 bps
1:2400bps
2: 4800 bps
3:9600bps
4: 19200bps
3
〇
345H
H-70
Communication
setting frequency
ratio
0.01
~
5.00 1.00
●
346H
H-71
Communications
timeout time
0.0
~
6500.0 second
10.0
●
347H
H-72
RS485
Communication
disconnection action
mode
0:close-down
1:Continued operation
0
●
348H
H-73 Response
delayed 0.001
~
1.000 second
0.005
●
349H
H-74
Moment stop
deceleration voltage
lower
0%
~
200% 20%
●
34AH
H-75
Moment stop
deceleration voltage
upper
0%
~
200% 90%
●
34BH
H-76
Moment stop
deceleration benefit
0.01
~
10.00 2.00
●
34CH
H-77
Voltage recover
steady time
0.0
~
100.0s 2.0s
●
34DH
H-78 Reserved
34EH
H-79 Reserved
34FH
H-80 Reserved
350H
Содержание SI10