background image

2

Contents

VEGASON 63 • Four-wire 4 … 20 mA/HART

51864-EN-210616

Contents

1  For your safety ......................................................................................................................... 3

1.1  Authorised personnel ....................................................................................................... 3

1.2  Appropriate use ................................................................................................................ 3

1.3  Warning about incorrect use ............................................................................................. 3

1.4  General safety instructions ............................................................................................... 3

1.5  EU conformity ................................................................................................................... 3

1.6  NAMUR recommendations .............................................................................................. 4

1.7  Environmental instructions ............................................................................................... 4

2  Product description ................................................................................................................. 5

2.1  Configuration

 .................................................................................................................... 5

3 Mounting ................................................................................................................................... 6

3.1  Mounting instructions ....................................................................................................... 6

4  Connecting to power supply ................................................................................................... 7

4.1  Connection procedure ...................................................................................................... 7

4.2  Wiring plan, double chamber housing .............................................................................. 8

5  Set up with the display and adjustment module PLICSCOM .............................................. 9

5.1  Insert display and adjustment module .............................................................................. 9

5.2  Setup steps ...................................................................................................................... 9

5.3  Menu schematic ............................................................................................................. 12

6  Set up with smartphone/tablet, PC/notebook via Bluetooth ............................................. 14

6.1 Preparations ................................................................................................................... 14

6.2 Connecting ..................................................................................................................... 15

6.3  Sensor parameter adjustment ........................................................................................ 16

7 Supplement ............................................................................................................................ 17

7.1  Technical data ................................................................................................................ 17

Information:

This quick setup guide enables quick setup and commissioning of 

your instrument.

You can find supplementary information in the corresponding, more 

detailed Operating Instructions Manual as well as the Safety Manual 

that comes with instruments with SIL qualification. These manuals are 

available on our homepage.

Operating instructions VEGASON 63 - 4 … 20 mA/HART - Four-

wire: Document-ID 28780

Editing status of the quick setup guide: 2021-06-15 

Содержание VEGASON 63

Страница 1: ...Quick setup guide Ultrasonic sensor for continuous level measurement VEGASON 63 Four wire 4 20 mA HART Document ID 51864...

Страница 2: ...ule PLICSCOM 9 5 1 Insert display and adjustment module 9 5 2 Setup steps 9 5 3 Menu schematic 12 6 Set up with smartphone tablet PC notebook via Bluetooth 14 6 1 Preparations 14 6 2 Connecting 15 6 3...

Страница 3: ...plying with all prevailing regulations and directives The instrument must only be operated in a technically flawless and reliable condition The operator is responsi ble for the trouble free operation...

Страница 4: ...ations are accepted as the standard in field instrumentation The device fulfils the requirements of the following NAMUR recom mendations NE 21 Electromagnetic compatibility of equipment NE 43 Signal l...

Страница 5: ...pprovals process seal process temperature signal output voltage supply protection protection class Data matrix code for VEGA Tools app SIL identification with SIL rating ex works Move to www vega com...

Страница 6: ...the so called dead zone in which measurement is not possible is maintained The exact value of the dead zone is stated in chapter Technical data 1 2 Fig 1 Minimum distance to the max level 1 blocking...

Страница 7: ...e wire ends into the open terminals according to the wir ing plan Fig 3 Connection steps 5 and 6 7 Press down the opening levers of the terminals you will hear the terminal spring closing 8 Check the...

Страница 8: ...pply VEGASON 63 Four wire 4 20 mA HART 51864 EN 210616 4 2 Wiring plan double chamber housing 4 20 mA PE L N L1 N GND 1 2 1 2 3 4 4 20mA IS Fig 4 Wiring plan double chamber housing 1 Voltage supply 2...

Страница 9: ...positions in 90 offset can be selected and turn to the right until it clicks into place 3 Screw housing lid with inspection window tightly back on Disassembly is carried out in reverse order The disp...

Страница 10: ...plica tion for example Aqueous solution Medium Liquid 4 Select in the menu item Application the vessel the application and the vessel form for example Storage tank Vessel shape Storage tank The sensor...

Страница 11: ...and weld joints on the vessel walls cause interfering reflections which can impair the measurement A false echo storage detects and marks these false echoes so that they are no longer taken into accou...

Страница 12: ...Depending on the version and application the highlighted menu windows may not always be available Basic adjustment Basic adjustment 1 Display Diagnostics Service Info Min adjustment 1 1 0 00 4 000 m...

Страница 13: ...djustment 4 Display Diagnostics Service Info False signal suppression 4 1 Change now Extended setting 4 2 None Current output 4 3 Characteristic 4 20 mA Fail mode 3 6 mA Min current 3 8 mA Simulation...

Страница 14: ...tooth 1 Switch On Bluetooth active Off Bluetooth not active The security concept of Bluetooth operation absolutely requires that the default setting of the sensor PIN be changed This prevents unau tho...

Страница 15: ...PIN is still effective Note Bluetooth access can only be established if the current sensor PIN differs from the default setting 0000 It is possible both when the PIN is deactivated and when it is acti...

Страница 16: ...essage Con necting is displayed For the first connection the operating device and the sensor must authenticate each other After successful authentication the next con nection functions without authent...

Страница 17: ...ween lower edge of the transducer and medium surface Measuring range Liquids up to 15 m 49 21 ft Bulk solids up to 7 m 22 97 ft Dead zone 0 6 m 1 969 ft Electromechanical data version IP66 IP67 Cable...

Страница 18: ...18 Notes VEGASON 63 Four wire 4 20 mA HART 51864 EN 210616...

Страница 19: ...19 Notes VEGASON 63 Four wire 4 20 mA HART 51864 EN 210616...

Страница 20: ...ing scope of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change withou...

Отзывы: