75
11 Supplement
VEGAPULS 67 • Profibus PA
36533-EN-170405
Repeatability
≤ ±1 mm
Deviation with bulk solids
The values depend to a great extent on the application.
Binding specifications are thus not possible.
Deviation under EMC influence
≤ ±30 mm
Variables influencing measurement accuracy
Temperature drift - Digital output
±3 mm/10 K, max. 10 mm
Additional deviation through electromag-
netic interference acc. to EN 61326
< ±50 mm
Characteristics and performance data
Measuring frequency
K-band (26 GHz technology)
Measuring cycle time approx.
700 ms
Step response time
2)
≤ 3 s
Beam angle
3)
10°
Emitted HF power (depending on the parameter setting)
4)
Ʋ Average spectral transmission power
density
-14 dBm/MHz EIRP
Ʋ Max. spectral transmission power
density
+43 dBm/50 MHz EIRP
Ʋ Max. power density at a distance of
1 m
< 1 µW/cm²
Ambient conditions
Ambient, storage and transport tempera-
ture
-40 … +80 °C (-40 … +176 °F)
Process conditions
Process temperature (measured on the
process fitting)
-40 … +80 °C (-40 … +176 °F)
Vessel pressure
-1 … 2 bar (-100 … 200 kPa/-14.5 … 29.0 psig)
Vessel pressure - Version with adapter
flange from DN 100 PP or PP-GF 30
-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)
Vibration resistance
Ʋ With adapter flange
2 g at 5 … 200 Hz according to EN 60068-2-6 (vibration
with resonance)
Ʋ with mounting strap
1 g at 5 … 200 Hz according to EN 60068-2-6 (vibration
with resonance)
Shock resistance
100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
2)
Time span after a sudden measuring distance change by max. 0.5 m in liquid applications, max 2 m with bulk
solids applications, until the output signal has taken for the first time 90 % of the final value (IEC 61298-2).
3)
Outside the specified beam angle, the energy level of the radar signal is 50% (-3 dB) less.
4)
EIRP: Equivalent Isotropic Radiated Power.