VEGAPULS 67 • Profibus PA
36533-EN-170405
Approvals
Instruments with approvals can have different technical specifications depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded under www.vega.com, "
Instrument
search (serial number)
" as well as in the download area.
11.2 Communication Profibus PA
Instrument master file
The instrument master file (GSD) contains the characteristic data of the Profibus PA instrument.
These data are, e.g. the permissible transmission rates as well as information on diagnostics values
and the format of the measured value outputted by the PA instrument.
A bitmap file is also provided for the Profibus network planning tool. This file is installed automati-
cally when the GSD file is integrated. The bitmap file is used for symbolic indication of the PA instru-
ment in the configuration tool.
ID number
Each Profibus instrument gets an unambiguous ident number (ID number) from the Profibus user
organisation (PNO). This ID number is also included in the name of the GSD file. Optionally in ad-
dition to this manufacturer-specific GSD file, PNO also provides a general so-called profile-specific
GSD file. If the general GSD file is used, the sensor must be set to the profile-specific ident number
via the DTM software. By default, the sensor operates with the manufacturer-specific ID number.
When using the instruments on a segment coupler SK-2 or SK-3, no special GSD files are required.
The following table shows the instrument ID and the GSD file names for VEGAPULS radar sensors.
Device name
Instrument ID
GSD file name
VEGA
Instrument class in
profile 3.02
VEGA
Profile-specific
VEGAPULS WL 61
0x0CDB
0x9702
PSWL0CDB.GSD
PA139702.GSD
VEGAPULS 61
0x0BFC
0x9702
PS610BFC.GSD
PA139702.GSD
VEGAPULS 62
0x0BFD
0x9702
PS620BFD.GSD
PA139702.GSD
VEGAPULS 63
0x0BFE
0x9702
PS630BFE.GSD
PA139702.GSD
VEGAPULS 65
0x0BFF
0x9702
PS650BFF.GSD
PA139702.GSD
VEGAPULS 66
0x0C00
0x9702
PS660C00.GSD
PA139702.GSD
VEGAPULS 67
0x0C01
0x9702
PS670C01.GSD
PA139702.GSD
VEGAPULS SR 68
0x0CDC
0x9702
PSSR0CDC.GSD
PA139702.GSD
VEGAPULS 68
0x0C02
0x9702
PS680C02.GSD
PA139702.GSD
VEGAPULS 69
0x0BFA
0x9702
VE010BFA.GSD
PA139702.GSD
Cyclical data traffic
The master class 1 (e.g. PLC) cyclically reads out measured values from the sensor during opera-
tion. The below block diagram below shows which data can be accessed by the PLC.