9
3 Product description
VEGAPULS 66 • 4 … 20 mA/HART - two-wire
28438-EN-170927
3
2
1
Fig. 1: VEGAPULS 66 - flange version with plastic housing
1 Housing cover with integrated PLICSCOM (optional)
2 Housing with electronics
3 Process fitting with antenna system
The type label contains the most important data for identification and
use of the instrument:
•
Instrument type
•
Article and serial number device
•
Article numbers, documentation
•
Technical data: Approvals, antenna type, process fitting, process
seal/temperature, signal output, voltage supply, protection, protec-
tion class
•
SIL identification (with SIL rating ex works)
With the serial number, you can access the delivery data of the instru-
ment via "www.vega.com", "
VEGA Tools
" and "
Instrument search
".
You can find the serial number on the inside of the instrument as well
as on the type label on the outside.
This operating instructions manual applies to the following instrument
versions:
•
Hardware version < 2.0.0
•
Software version ≤ 3.8
3.2 Principle of operation
VEGAPULS 66 is a radar sensor in C-band (emitting frequency ap-
prox. 6 GHz) for continuous level measurement.
A special version of VEGAPULS 66 is available for each area of appli-
cation. The version with
flange and horn antenna
is particularly suit-
Type label
Scope of this operating
instructions manual
Application area