36
VEGAPULS 56K
DN 50
ø50
Mounting and installation
Lockable measuring pipe on a pipe antenna system
Ball valve
Row of holes in one axis with the hole
holes and slots must be positioned in two rows
displaced by 180
°
. The mounting of the radar
sensor is then such that the hole is in one axis
with the row of holes.
Standpipe with ball valve
When using a ball valve in a surge pipe, it is
possible to carry out maintenance and ser-vice
work without opening the vessel (e.g. with
liquid gas or toxic products).
The ball valve diameter must correspond to
the pipe size and provide a flush surface when
in open position.
Note that a surge pipe ventilation is available.
Installation error in standpipe
Missing ventilation hole
Surge pipe ventilation
Hole
Deflector