7 Setup
VEGAPOINT 21 • Transistor (NPN/PNP)
56623-EN-210210
You can enter a delay time from 0 to 60 seconds.
Reset delay (DR1)
The reset delay (DR) extends the reaction time until the sensor
switches over when the sensor tip becomes free.
You can enter a delay time from 0 to 60 seconds.
With this menu item you can set the function of the 360° status indica-
tion.
•
Brightness of the 360° status indication
•
Signalling
•
Fault
•
Switching output
•
Operating status
Brightness of the 360° status indication
Brightness selection in 10 percent increments (0 %, 10 %, 20 %
30 %, 40 % … 100 %)
Signalling
Acc. to NAMUR NE 107
In this menu item you can select the standardized signalling accord-
ing to NAMUR NE 107 or an individual signalling.
If you have selected signalling according to NAMUR NE 107, the
signalling is set as follows:
•
Failure/malfunction - Red
•
Operating status/output 1 closed - Yellow
•
Operating status/output 1 open - Green
In addition there are the following status indications:
•
Simulation - red flashing
•
Maintenance required - green flashing
Individual signalling
If you have selected "Individual signalling", you can select the respec-
tive LED colour for the switching states "Failure", "Switching output"
and "Operating condition" separately in the following menu items.
The following colours are available:
Red, yellow, green, blue, white, orange, no signalling. You can also set
all colours individually in addition.
You can also have every status displayed flashing additionally.
You can use the "
Access protection
" function to block or release ac-
cess via the Bluetooth interface.
Bluetooth access code
With the function "
Bluetooth access code
" you can release the
Bluetooth data connection.
To activate the function, you must enter the six-digit access code.
You can find the Bluetooth access code in the "
PINs and Codes
"
sheet of the shipping documentation.
Indication
Access protection