![Vega VEGAPOINT 21 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/vega/vegapoint-21/vegapoint-21_operating-instructions-manual_3893558018.webp)
18
5 Connecting to power supply
VEGAPOINT 21 • Transistor (NPN/PNP)
56623-EN-210210
For this plug version, standard cable with round wire cross-section
can be used. Cable diameter 4.5 … 7 mm, protection IP65.
1. Loosen the screw in the cover of the plug connector
2. Open the cover and remove it
3. Press the plug insert downwards
4. Loosen the screws of the strain relief and cable entry
4
3
2
1
3
2
1
Fig. 10: Loosen the plug insert
1 Plug insert
2 Strain relief
3 Cable gland
4 Plug housing
5. Remove approx. 5 cm of the cable mantle, strip approx. 1 cm
insulation from the individual wires
6. Lead the cable through the cable gland into the plug housing
7. Connect the wire ends to the screw terminals according to the
wiring plan
1
5
2
3
4
Fig. 11: Connection to the screw terminals
1 Cable gland
2 Cover
3 Plug housing
4 Plug insert
5 Plug seal
8. Snap the plug insert into the plug housing and insert the sensor
seal
Information:
Note the correct arrangement, see illustration
Valve plug ISO 4400 with