S
everal antenna versions are available for di
ff
erent applications
.
1
2
3
4
F
ig
.
2
:
A
ntenna versions
1
E
ncapsulated horn antenna with
PTFE
cover
2
P
lastic encapsulated antenna with
PP
cover
3
H
orn antenna
4
VEGAMIP
61
with angled antenna extension
T
he emitting unit transmits a focused microwave signal via horn
antenna to the receiving unit on the opposite side
.
I
f there is medium
between emitting and receiving unit
,
the signal is damped
.
T
his
change is detected by the built
-
in electronics module and converted
into a switching command
.
3
.
3
P
ackaging
,
transport and storage
Y
our instrument was protected by packaging during transport
.
I
ts
capacity to handle normal loads during transport is assured by a test
according to
DIN EN
24180
.
T
he packaging of standard instruments consists of environment
-
friendly
,
recyclable cardboard
.
F
or special versions
,
PE
foam or
PE
foil
is also used
.
D
ispose of the packaging material via specialised
recycling companies
.
T
ransport must be carried out under consideration of the notes on the
transport packaging
.
N
onobservance of these instructions can cause
damage to the device
.
T
he delivery must be checked for completeness and possible transit
damage immediately at receipt
.
A
scertained transit damage or
concealed defects must be appropriately dealt with
.
F
unctional principle
P
ackaging
T
ransport
T
ransport inspection
VEGAMIP U
61
• -
R
elay
9
3
P
roduct description
-
EN
-
100531