N
ote
:
T
o contact the instrument
,
a corresponding
IP
address must be
available in the instrument
.
E
ach instrument is preset to address
192
.
168
.
200
.
200
.
E
nter the address and subnet mask corresponding
to your network directly via the keyboard
.
A
s an alternative
,
addressing
is also possible via
DHCP
and a host name
.
B
rie
fl
y interrupt the
operating voltage after each modi
fi
cation
,
then the instrument is
accessible via its
IP
address or host name everywhere in the network
.
I
n addition
,
these speci
fi
cations must be entered in the
DTM
(
see
chapter
"
P
arameter adjustment with
PACT
ware
"
).
2
3
1
F
ig
.
7
:
C
onnection of the
PC
via
E
thernet
1
E
thernet interface of the
PC
2
E
thernet connection cable
(
C
ross
-
O
ver cable
)
3
E
thernet interface
T
he
RS
232
interface is particularly suitable for easy modem
connection
.
E
xternal analog
,
ISDN
and
GSM
modems with standard
interface can be used
.
T
he necessary
RS
232
modem connection
cable is included with the delivery
.
T
o reduce
EMC
interference
,
you
should mount the supplied ferrite bead on the
RS
232
modem
connection cable
.
V
ia a visualisation software
,
measured values can
be retrieved remotely and further processed
.
A
lternatively
,
the
autonomous time or event controlled transmission of measured values
via e
-
mail is also possible
.
R
emote parameter adjustment of the
instrument and the connected sensors is also possible with
PACT
ware
.
C
onnection of the mo
-
dem via
RS
232
32
VEGAMET
624
•
4
…
20
m
A
/
HART
signal conditioning instrument
7
S
etup with
PACT
ware
28969
-
EN
-
091116