W
hen changing the measurement
,
the assistant can be opened any
time
.
T
he subsequent steps can be also reached via the classical
menu guidance
.
T
he description of the individual menu items is
available in the classical menu guidance
.
I
n chapter
"
A
pplication
examples
"
you will
fi
nd further information to the setup
.
T
he main menu is split into six areas with the following functions
:
l
D
evice settings
:
I
ncludes the device
-
TAG
,
settings for network
connection such as date
/
time setting
, …
l
M
easurement loop
:
I
ncludes settings for input selection
,
adjust
-
ment
,
damping
,
linearization
,
scaling
,
outputs
, …
l
D
isplay
:
I
ncludes settings to the displayed measured value
,
languafe setting und brightness of the background lighting
l
D
iagnosis
I
ncludes information to the device status
,
error
messages
,
input current
,
digital inputs
l
F
urther settings
:
I
ncludes simulation
,
reset
,
PIN
,
sensor address
,
…
l
I
nfo
:
S
hows serial number
,
software version
,
last change
,
instru
-
ment features
,
MAC
addr
., …
à
S
elect the requested menu item via the respective keys and
con
fi
rm with
[
OK
]
.
Y
ou can assign an unambiguous name to
VEGAMET
391
via the
D
evice
-
TAG
.
T
his function is recommended when several instruments
are implemented and a good documentation of larger systems is
required
.
à
C
arry out your settings via the respective keys and save with
[
OK
]
.
F
or instruments with
E
thernet interface
,
the instrument must be
provided with an
IP
address
/
S
ubnet mask suitable for your network
.
D
epending on the network
,
the adjustment of a gateway address is
also necessary
.
A
s an alternative
,
addressing via
DHCP
and a host
name is also possible
.
T
hese speci
fi
cations are available from your
network administrator
.
K
eep in mind that your settings are only
e
ff
ective after a restart of
VEGAMET
391
.
F
urther information to these
network parameters is available in the supplementary instructions
manual
"
RS
232
/
E
thernet connection
"
and in the online help of the
corresponding
DTM
s
.
C
lassical menu gui
-
dance
/
main menu
D
evice settings
-
D
evice
-
TAG
D
evice settings
-
H
ost
N
ame
/
IP
addr
.
VEGAMET
391
•
4
…
20
m
A
/
HART
signal conditioning instrument
19
6
S
etup with the integrated indicating and adjustment unit
36032
-
EN
-
091116