VEGALOG 571
39
Set-up
Switch on VEGALOG and connect the CPU-
card of VEGALOG to the PC via the RS␣ 232-
interface cable. Then start VVO. When VVO
has already been started and you then con-
nect VEGALOG, push the function key
F8
on
the PC. The screen then shows the picture
below. First click on Configuration and then
on
Measuring system
to configure the
VEGALOG.
When you have enquired the EV-card (EV
stands for input - VBUS-sensor), you can
click on the button
Sensor survey
. All the
VBUS-sensors connected to the EV-card are
listed in the window “Sensor survey Card-no.
X“.
In this window, you can modify sensor desig-
nations (Sensor-TAG) and enter serial num-
bers manually. Click on the appropriate
sensor and then click on
Configure
.
Your VEGALOG is now shown in your con-
figuration. By clicking on a card (e.g. CPU-
card) or clicking the buttons
<<
and
>>
you
can enquire the card info of all available VE-
GALOG-cards. If you have clicked on the
CPU-card (as shown), you can carry out a
Restart
(equivalent to briefly switching off the
CPU) or a
Reset
. With
Reset
, all VEGALOG
measurement loops which have already been
created, are deleted.
With the AR-card (AR stands for relay output)
and the AT-card (AT stands for transistor
output), you can carry out pre-adjustments
as on the EV-card. Click on
configure
to
open the window “Configure switching out-
put“.