22
6 Set up with the display and adjustment module
VEGADIS 82 • 4 … 20 mA/HART
45300-EN-170724
6 Set up with the display and adjustment
module
6.1 Short description
The display and adjustment module is used for measured value
display, adjustment and diagnosis. It can be mounted in the following
housing versions and instruments:
•
All continuously measuring sensors in single as well as double
chamber housing version (optionally in the electronics or terminal
compartment)
•
External display and adjustment unit
Note:
You can find detailed information on adjustment in the operating
instructions manual "
Display and adjustment module
".
6.2 Insert display and adjustment module
The display and adjustment module can be inserted into VEGADIS
82 and removed again at any time. It is not necessary to interrupt the
power supply.
Proceed as follows for mounting the display and adjustment module:
1. Unscrew the housing lid
2. Place the display and adjustment module in the desired position
on the electronics (you can choose any one of four different posi-
tions - each displaced by 90°)
3. Press the display and adjustment module onto the electronics
and turn it to the right until it snaps in
4. Screw housing lid with inspection window tightly back on
Disassembly is carried out in reverse order.
Function/Configuration
Mount/dismount display
and adjustment module