T
echnical data
18
H
ydrostatic
–
L
evel and pressure measurement
P
ower supply
-
F
oundation
F
ieldbus
S
upply voltage
-
non
-
E
x instrument
9
…
32
V DC
-
EE
x ia instrument
9
…
24
V DC
S
upply voltage with lighted indicating and adjustment module
12
)
-
non
-
E
x instrument
12
…
32
V DC
-
EE
x ia instrument
12
…
24
V DC
P
ower supply by
/
max
.
number of sensors
-
H
1
F
ieldbus cable
/
V
oltage supply
max
.
32
(
max
.
10
with
E
x
)
E
lectrical protective measures
P
rotection
-
H
ousing
,
standard
IP
66
/
IP
67
13
)
-
A
lu and stainless housing
,
optionally available
IP
66
/
IP
68
(
1
bar
)
14
)
-
T
ransmitter in
IP
68
version
IP
68
-
R
emote housing
IP
65
O
vervoltage category
III
P
rotection class
II
A
vailable approvals or approvals applied for
15
)
16
)
ATEX
ia
ATEX II
1
G
,
1
/
2
G
,
2
G EE
x ia
IIC T
6
ATEX
ia and d
ATEX II
1
/
2
G
,
2
G EE
x d ia
IIC T
6
ATEX D
ATEX II
1
/
2
D
,
2
D IP
6
X T
IEC
IEC E
x ia
IIC T
6
FM
FM
,
C
l
.
I
,
D
iv
2
(
NI
)
+
l
I
.
II
,
II
,
D
iv
1
(
DIP
),
FM C
l
.
I
-
III
,
D
iv
1
(
IS
),
FM C
l
.
I
-
III
,
D
iv
1
(
IS
)
+
C
l
.
I
-
III
,
D
iv
1
G
r
.
C
-
G
(
XP
)
S
hip approval
GL
,
LRS
,
ABS
,
CCS
,
RINA
,
DNV
O
thers
WHG
CE
conformity
EMC
(
89
/
336
/
EWG
)
E
mission
EN
61326
:
1997
(
class
B
),
susceptibility
EN
61326
:
1997
/
A
1
:
1998
LVD
(
73
/
23
/
EWG
)
EN
61010
-
1
:
2001
F
unctional safety
(
SIL
)
Y
ou will
fi
nd detailed information in the
"
S
upplementary in
-
structions manual
-
F
unctional safety
VEGABAR
series
50
and
60
"
or under www
.
vega
.
com
.
F
unctional safety acc
.
to
IEC
61508
-
4
-
S
ingle channel architecture
(
1
oo
1
D
)
up to
SIL
2
-
D
ouble channel architecture
(
1
oo
2
D
)
up to
SIL
3
E
nvironmental instructions
VEGA
environment management system
17
)
certi
fi
ed acc
.
to
DIN EN ISO
14001
12
)
T
his function is for instruments with
S
t
E
x
,
WHG
or ship approval as well as country
-
speci
fi
c approvals such as those acc
.
to
FM
or
CSA
,
available at a later date
.
13
)
I
nstruments with gauge pressure measuring ranges cannot detect the ambient pressure when submerged
,
e
.
g
.
in water
.
T
his can lead to
falsi
fi
cation of the measured value
.
14
)
O
nly with instruments with absolute pressure ranges
.
15
)
D
eviating data in
E
x applications
:
see separate safety instructions
.
16
)
D
epending on order speci
fi
cation
.
17
)
Y
ou can
fi
nd detailed information under www
.
vega
.
com
.
29235
-