background image

 

Page | 4  

 

 

EZ-OTDR Mode 

 

-

 

Choose the wavelengths you want to test. The tester will select the best settings for resolutions, pulse width 
and distance. 

-

 

If you have spans on your link, ex: initial launch fiber at your side or the remote side, then go to Span and 
insert the span information 

-

 

V-Scout is for automating several tests sequentially with different settings and then combining them all into 
one diagram to accurately characterize all events that might require different pulsewidths and resolution. For 
example: you can select a short PW to detect near events accurately and another test in the sequence to test 
with a much longer PW to detect far events accurately. 

-

 

A. Thresholds: Analysis thresholds which define how the tester identifies the different events. 
You can customize these thresholds by pressing the Pencil icon. 

-

 

P/F Thresholds: Pass/Fail Thresholds. Any event exceeding those PASS/FAIL thresholds will be detected as fail 

-

 

AutoSave: after every test. Set how the filename of the trace will increment and what additional information 
you want to auto insert into the filename (Wavelength, PW, Date.. etc) 

-

 

Cloud: If you have created an account on Fiberizer Cloud (free service), then you can insert here your login 
credentials so that the tester can upload the test results to your account 

-

 

Once done, press Start to run the test 

 

 

Содержание OTDR FX150+ Series

Страница 1: ...TELECOMTEST SOLUTIONS 11 477 Warrigal Rd Moorabbin VIC 3189 Tel 1300 468 469 sales telecomtest com au FX150 Quick Start Guide OTDR OPM OLS ORL Fiber Scope Including EZ Mode...

Страница 2: ...il your hear a beep Do the same thing if you want to power off Softkeys Home Tap to return to the OTDR Main Menu Escape Exit Tap to return to the previous screen Tap to hide unhide the side menus V ke...

Страница 3: ...this mode if you don t want to configure any optical settings The unit will make the best selection for the optical pulse settings V Scout LinkMap Choose this mode if you are mainly interested in the...

Страница 4: ...urately and another test in the sequence to test with a much longer PW to detect far events accurately A Thresholds Analysis thresholds which define how the tester identifies the different events You...

Страница 5: ...for automating several tests sequentially with different settings and then combining them all into one diagram to accurately characterize all events that might require different pulsewidths and resolu...

Страница 6: ...u can go to Measure tab to start making manual measurements on the activated trace Measure You can make manual measurements for splice loss reflectance and ORL Press the softkey Markers to enable A an...

Страница 7: ...ent to be saved later on You can acquire as many as you want before saving the list of acquired measurements Setting a Reference Level press dB Enter to enter manually the reference level value you wa...

Страница 8: ...ress the V key For more information please refer to the following documents FX150 platform User Manual OTDR User Manual Link VS500 Fiber Scope User Manual Link Fiberizer Quick Start Guide Link Fiberiz...

Отзывы: