Содержание MPA SCM-210

Страница 1: ......

Страница 2: ...MPA INSTALLATION GUIDE ii MPA Installation Guide Document No CO 402227...

Страница 3: ...3 Front of MPA 2nd Generation Chassis including SCM 210 1 2 1 4 MPA Slot Locations 1 2 1 5 Chassis Mounting Brackets 1 3 1 6 How to install the chassis into a rack 1 3 1 7 EMI Shielding and Airflow Wa...

Страница 4: ...3 4 Understanding Test Units 3 6 3 5 AMC Test Module Cards and Slot Locations including SCM 210 3 7 3 6 How the MPA Supports Multiple Concurrent Users 3 8 3 7 System Date and Time 3 11 3 8 Chassis Cl...

Страница 5: ...mation The rack mounted Multi Protocol Analyzer MPA system and the various Protocol Processors described in this publication may be protected by one or more patents on file with the United States Pate...

Страница 6: ...nductor plus ground IEC 320 C 14 connector on one end and a wall socket plug on the other end that is certified for use in the country of installation The entire cord set must be certified for use in...

Страница 7: ...were emitting laser light Always leave protective covers on optical connectors to prevent damage and prevent laser emissions Field Service This equipment is not intended to be serviced in the field A...

Страница 8: ...Copyright and Safety Information viii MPA Installation Guide Document No CO 402227 This page intentionally left blank...

Страница 9: ...rt the same MPM modules originally sold with the first generation MPA chassis However the slot numbers in the second generation chassis are in different positions and the second generation chassis is...

Страница 10: ...replacing the MCH and AMC Processor with an SCM 210 See Chapters 3 4 and 3 5 for the GUI tab names associated with the six slot locations For MPA system containing an AM4022 Processor and MCH Control...

Страница 11: ...ntilation is required on the top or the bottom of the chassis 2 Lift and position the chassis into place Align the four screw slots on the mounting brackets with the screw holes on the rack s rails 3...

Страница 12: ...hassis for better thermal profile Warning Never turn the chassis Power on without both fan trays fully inserted 1 9 Air Filter Swap The MPA chassis provides a front replaceable air filter next to the...

Страница 13: ...a use a power cord maximum six foot length with a type SJT 18 AWG two conductor with ground IEC 320 C14 connector on one end and a NEMA 5 15 connector on the other end For Europe and other countries o...

Страница 14: ...ors designed for 48V input power supply 3 Avoid Electric Overload To avoid electric shock fire hazard or damage to the instrument do not apply a higher voltage a The DC Power Supply is designed to be...

Страница 15: ...addition Test Module slot where the AMC Processor used to occupy The new SCM 210 is available beginning in March of 2018 The new SCM 210 supports the following features Figure 1 12 SCM 210 READY LED s...

Страница 16: ...handle to pull the module out of the chassis When inserting a new module into the chassis verify the module is properly aligned with the guide rails Push on the front of the card until it contacts the...

Страница 17: ...een When the system is shipped from the factory the SCM 210 s default IP Address is set to 192 168 0 10 with a Subnet Address of 255 255 255 0 and Router Address of 192 168 0 1 This chapter will cover...

Страница 18: ...ess with a USB Flash Drive The ability to change the MPA s IP Address using a USB flash drive e g pen drive is a very simple and easy method of changing the IP Address By attaching a USB flash drive c...

Страница 19: ...igure the MPA system for a Static IP Address a Change the file s IP Address Subnet Mask and Gateway to the appropriate settings for your network b By default this file is configured with the following...

Страница 20: ...to 45 seconds the system does not reboot this could indicate a The IP Address settings configured on the USB flash drive are the same as those already programmed on the MPA system b The mpa_ipconfig...

Страница 21: ...s from a VNC connection using the Remote GUI client from the MPA s VNC remote desktop connection Software Requirements Remote Client software See Chapter 3 for Installation Windows XP or newer Windows...

Страница 22: ...ss b By default DNS Address 1 Primary DNS is configured for 8 8 8 8 and DNS Address 2 Secondary DNS is configured for 8 8 4 4 These are public DNS addresses established by Google and only need to be m...

Страница 23: ...airflow inside the chassis Note Before you begin verify you have access to the Remote Client software The Remote Client software is needed for Remote GUI connections to access the system The Remote Cl...

Страница 24: ...Default DPI settings of 100 are recommended for optimum viewing 256 MB RAM or higher recommended for optimum performance 60 MB of free hard disk space A CD ROM drive if installing from a CD A standar...

Страница 25: ...software into a directory The default directory is C Program Files DLI RemoteClient 5 From the Remote GUI Directories dialog box select A Create Multiple Directories default for faster access and to...

Страница 26: ...tronic devices is to Reboot the MPA system a Follow the steps outlined in Chapter 4 Shutdown Procedure for turning the power Off b After the power to the device is turned off then push both of the Unl...

Страница 27: ...mote Client from the scroll list box and click the Add Remove button 5 Follow the on screen instructions 6 Open Windows Explorer and delete the Remote Client software s directory For example C Program...

Страница 28: ...MPM 10G Test Unit or Port consists of one OTN SONET SDH and PACKET Protocol Processor tabs for both Port 1 and Port 2 on each MPM 10G card Thus the Protocol Processor tabs for Test Unit 1 in the GUI c...

Страница 29: ...and P2 Thus the GUI refers to the first two test ports as S1 P1 and S1 P2 and the next two test ports as S2 P1 and S2 P2 and so on In the Figure 3 3 example the Slot 5 contains an MPM 100AR card MPM 1...

Страница 30: ...st Units and some Test Units might consist of one or more Protocol Processors Refer to the Understanding Test Units section in the User s Guide for additional information Permission levels determine t...

Страница 31: ...mode To gain the Lock in this situation you must be logged in with Admin privileges in order to Force an Unlock To Force an Unlock select this icon to open the Lock Unlock window and select the Force...

Страница 32: ...ir GUI FAULT If the module or circuit pack goes Out of Service the Fault icon appears on all Protocol Processors within the affected Test Unit The Elapsed Time will also display Out of Service The fau...

Страница 33: ...igure 3 4 Set the Date Time Also when an MPA system is connected to a network with Internet access the system s Date and Time will automatically update with the date and time obtained from the followi...

Страница 34: ...ecified External clock or an Internal clock with various clock out options Also each test port in the chassis can independently use a recovered looped timing mode By default the transmitted signals de...

Страница 35: ...l Stratum 3 clock source Chassis Internal option appears in the Clock Reference menu and CLK INT displays in the Quick LED Status area when selected The RJ 48 CLK A Out port is a 2 048 Mbps SETS clock...

Страница 36: ...timing from an external 1 544 MHz 75 ohm TTL timing source attached to the SMA CLK B In connector Chassis Ext 1 5 MHz option appears in the Clock Reference menu and CLK Ext 1 5 MHz displays in the Qui...

Страница 37: ...e Protocol Processor s Lock status in any way By default the INST protocol processor is not able to force an unlock of a Protocol Processor that is currently Locked by another user If the specified Pr...

Страница 38: ...uring the system s IP Address if needed PC with Windows XP or newer Windows operating system and web browsing software e g Internet Explorer Chrome Firefox etc Software release tca X Y ZZ tgz where X...

Страница 39: ...essing the Upload and Update Software button the tgz file will upload to the MPA system which can take several seconds followed by a System Software Update screen stating The software update process h...

Страница 40: ...8 0 51 In order to upgrade the software from Feature Set 8 0 x or earlier to Feature Set 8 1 x or later you must first perform an incremental software upgrade to Feature Set 8 0 51 The tca 8 0 51 tgz...

Страница 41: ...nd or SCPI 2 Pull out the Unlock Extraction handle to the first stop position on the SCM 210 a Note When an Unlock Extraction handle is pulled out to the first stop position the blue hot swap LED will...

Страница 42: ...unplugged b Push in up on the release button on the bottom side of the connector to unplug the Self Locking power cable Note The Unlock Extraction handles on the remaining MPM test cards do not need t...

Страница 43: ...r both telecommunication and data communications applications up to 100Gbps compliant to the 100GBASE LR4 specifications in the IEEE P802 3ba standard A CFP4 module multiplexes four 25Gbps electrical...

Страница 44: ...100Gbps MMC The required management controller on the AMC cards which interfaces to the MCMC on the MCH card MPA Multi Protocol Analyzer VeEX s MPA rackmount systems are a MicroTCA chassis systems us...

Страница 45: ...lecommunication applications that multiplexes four 4 data channels up to 10Gbps each into a single channel for optical interface rates up to 40Gbps QSFP28 Quad Small Form factor Pluggable 28 A QSFP28...

Страница 46: ...al Hierarchy A set of European fiber optic based standards similar to SONET SONET Synchronous Optical Network An American National Standards Institute ANSI standardized digital communication protocol...