DOC. NO. 5956.6K6.00
P. 16 / 28
8.5
Parameters for automatic hood type dishwashers
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
Enable “regeneration cycle” key (only for dishwashers with non-
continuous water softener) [See paragraph 9.1 DETERGENT
AND RINSE AID LEVEL SENSORS ACTIVATION].
-
0
1
0
ALARMS ENABLE
0 = alarms disabled (to disable also warnings see
and
);
1 = alarms enabled;
If this function is disabled, faults can be detected so display do not
shows any alarm code.
-
0
1
1
Air gap with float level sensor normally closed (the level sensor is
closed when the boiler is empty). E.g. the boiler level sensor for
machines with incorporated continuous water softener.
-
0
1
0
Forced start of a resin regeneration cycle (only for dishwashers
with incorporated continuous water softener). [See paragraph 9.2
DISHWASHERS WITH WASH TANK WATER CHANGE FRE-
QUENCY CONTROL].
-
0
2
0
Max. rinse water hardness (only for dishwashers with incorpo-
rated continuous water softener). After modifying, disconnect and
reconnect the machine's main power supply by means of the
main switch. [See paragraph 9.2 DISHWASHERS WITH WASH
TANK WATER CHANGE FREQUENCY CONTROL].
°fH
4
14
10
Boiler heating control.
Defines the max. permissible temperature difference during boiler
heating in a time interval of 2 minutes and 30 seconds.
°F
77
176
122
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
DELAY_K1
Time (during hood lifting) within which S3” must return to the rest
position.
0.1 s
0.0 s.
20.0 s
15
HOOD_TOUT
TIMEOUT – max. time allowed for complete hood opening/clos-
ing.
0.1 s
0.0 s
20.0 s
200
DELAY_K1_S3
During hood lowering, firstly S3” must cut in and then after a time
.
the bottom limit switch S3.
0.1 s
0.0 s.
20.0 s
15
DELAY_K
Time within which K and K’ must be both closed or both open.
0.1 s
0.0 s.
20.0 s
10
DELAY_S3
Time during hood lifting within which the bottom limit switch must
return to the rest position..
0.1 s
0.0 s.
20.0 s
20
DELAY_S5
Time during hood lowering within which the top limit switch must
return to the rest position.
0.1 s
0.0 s.
20.0 s
20
Displays the last alarm code relative to automatic hood type dish-
washers.
-
-
-
0
Parameter only valid for hood type models.
Hood lifting motor absorption threshold.
(50 units correspond to a current of approx. 1 ampere).
-
0
250
100