7
Console Wiring Inputs
This section details TLS4 power, communication, and device input connections and requirements.
Table 1. TLS4 Wiring Inputs
Connector
Description
Input Power
NOTE: The TLS4/8601 Series console is factory configured for either AC input power or DC input
power, but not both.
Universal AC power supply:100 to 249Vac, 50/60Hz, 2A maximum; or
DC power supply (optional): +24Vdc, 2A max. and +5Vdc, 4A max.
Um <= 250Vrms or 250Vdc
240 Vac input: 1 - N/L2 (black), 2 - Ground (green), 3 - L1 (red)
120 Vac Input: 1 - N/L2 (white), 2 - Ground (green), 3 - L1 (black)
+24/+5 Vdc Input: 1 - +24 (white), 2 - Ground (green), 3 - +5 (black). NOTE: This input wiring diagram is
only for consoles with DC Power option.
HV Relay
Outputs
2 Relay Outputs:
120/240 Vac, 5A; 30 Vdc, 5A;
Fuse ratings 5A, 250 Vac Type T (Slo-Blo)