5
VEC1090 A
REV101103
FIGURE 3A
(FRONT VIEW)
FIGURE 3B
(REAR VIEW)
Contact the Vector Technical Support Department at (954) 584-4446 or toll free: (866) 584-5504 for further information.
CONTROLS AND INDICATORS
There are four LED indicators and four switches that make up the controls and indicators for this charger. When a button
is pressed or the charger changes mode or charging stage, the charger sounds a single beep tone. Refer to Figure 4A
for locations of items on the Controls and Indicators panel.
FIGURE 4A
DIGITAL DISPLAY
FIGURE 4B
Circulating pattern
WARNINGS:
THERE ARE NO USER-SERVICEABLE PARTS IN THIS CHARGER. IN THE EVENT OF ANY OPERATING PROBLEM THAT THE
CHARGER’S BUILT-IN CIRCUIT PROTECTION CANNOT HANDLE, DO NOT OPEN THE
UNIT! IT MUST BE RETURNED TO VECTOR FOR PROFESSIONAL TESTING AND REPAIR. OPENING THE UNIT WILL VOID THE
MANUFACTURER'S WARRANTY.
ON/OFF
- this prepares the charger to be placed in any of the operating modes. Pressing the ON/OFF button
immediately stops any operating mode and the display shows the circulating pattern (Figure 4B).
Alternator Voltage Check
enables a five second check that measures the battery voltage. This check is repeated at
various electrical load levels and the tests allow the user to determine if the alternator can keep up with the loads. It
can indicate alternator service may be required.
Battery Recondition
is an automatic mode that once started continues for 24 hours and then stops. A series of electrical
pulses are sent into the battery enabling the plate to once again accept and release energy so the battery will perform
at greater capacity.. More than 24 hours may be needed to restore. If 5 cycles does not improve battery performance,
discontinue and re-cycle the battery.
2/10/20A
allows the user to select the charger rate based on battery size. This selection and the actual battery charge
rate are monitored by the microprocessor and the charger will stop charging if the rate is too fast or too slow for the
battery size or condition.
Periodic reconditioning is recommended to maintain a battery’s optimum performance.