background image

5

VEC1090 A

REV101103

FIGURE 3A 

(FRONT VIEW)

FIGURE 3B  

(REAR VIEW)

Contact the Vector Technical Support Department at (954) 584-4446 or toll free: (866) 584-5504 for further information.

CONTROLS AND INDICATORS

There are four LED indicators and four switches that make up the controls and indicators for this charger. When a button
is pressed or the charger changes mode or charging stage, the charger sounds a single beep tone. Refer to Figure 4A
for locations of items on the Controls and Indicators panel.

FIGURE 4A

DIGITAL DISPLAY

FIGURE 4B

Circulating pattern

WARNINGS:

THERE ARE NO USER-SERVICEABLE PARTS IN THIS CHARGER. IN THE EVENT OF ANY OPERATING PROBLEM THAT THE
CHARGER’S BUILT-IN CIRCUIT PROTECTION CANNOT HANDLE, DO NOT OPEN THE
UNIT!  IT MUST BE RETURNED TO VECTOR FOR PROFESSIONAL TESTING AND REPAIR. OPENING THE UNIT WILL VOID THE
MANUFACTURER'S WARRANTY.

ON/OFF

- this prepares the charger to be placed in any of the operating modes. Pressing the ON/OFF button

immediately stops any operating mode and the display shows the circulating pattern (Figure 4B).

Alternator Voltage Check

enables a five second check that measures the battery voltage. This check is repeated at

various electrical load levels and the tests allow the user to determine if the alternator can keep up with the loads. It
can indicate alternator service may be required.

Battery Recondition

is an automatic mode that once started continues for 24 hours and then stops. A series of electrical

pulses are sent into the battery enabling the plate to once again accept and release energy so the battery will perform
at greater capacity.. More than 24 hours may be needed to restore. If 5 cycles does not improve battery performance,
discontinue and re-cycle the battery.

2/10/20A

allows the user to select the charger rate based on battery size. This selection and the actual battery charge

rate are monitored by the microprocessor and the charger will stop charging if the rate is too fast or too slow for the
battery size or condition.

Periodic reconditioning is recommended to maintain a battery’s optimum performance.

Содержание VEC1090 A

Страница 1: ... plug rather than cord when disconnecting charger 4 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a Pins on plug of extension cord are the same number size and shape as those of plug on charger b Extension cord is properly wired and in good electrical cond...

Страница 2: ...plug The plug must be plugged into a properly installed and grounded 110 120VAC outlet in accordance with all local codes and ordinances See Figure 1 This battery charger is for use on a 110 120VAC circuit and has a grounding plug that looks like the plug shown in FIGURE 1A If a properly grounded outlet is not available a temporary adapter like the adapter shown in FIGURE 1B may be used to connect...

Страница 3: ...C output clamps only after unplugging AC cord from outlet 2 Never allow clamps to touch each other 3 Attach clamps to battery posts and check for secure connection This will hold clamps securely on terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Position ...

Страница 4: ...urrent is reduced to allow for the maximum proper internal chemical energy transfer Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective battery charge level step down regulation mode Ideal for topping off batteries that have been in storage At the conclusion of Stage 3 the unit will BEEP signaling the co...

Страница 5: ...sing the ON OFF button immediately stops any operating mode and the display shows the circulating pattern Figure 4B Alternator Voltage Check enables a five second check that measures the battery voltage This check is repeated at various electrical load levels and the tests allow the user to determine if the alternator can keep up with the loads It can indicate alternator service may be required Ba...

Страница 6: ... 5 and on the back of charger FIGURE 5 Below the Digital Display are series of four LEDS that light on the following conditions FAULT Lights when any of several faults are detected see F01 through F05 Codes as described above If the Fault LED lights refer to TROUBLESHOOTING for details REV POLARITY Lights when clamps are incorrectly connected to battery terminals CHARGING COMPLETE Indicates Batter...

Страница 7: ...charge rate to appropriate setting 2 10 20A according to battery size POSITIVE GROUNDED VEHICLE Connect the NEGATIVE BLACK charger clamp to the NEGATIVE NEG N ungrounded battery post Then connect the POSITIVE RED battery clamp to the vehicle chassis or engine part away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body d Plug battery charger power cord into ...

Страница 8: ...d to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Whenever a lead acid battery begins to discharge lead sulfate an insulator begins to build up on the battery s internal plates This reduces the ability of the battery to hold a full charge When that battery has an immediate charge most of the lead sulfate is dissolve...

Страница 9: ... any battery fluid that will cause corrosion of the copper clamps Clean the outside case of the charger with a soft cloth and if necessary mild soap solution Do not allow liquid to enter the charger Do not operate when charger is wet Keep the charger cords loosely coiled during storage to prevent damage to the cords Do not use charger if cords or clamps have been damaged in any way call Vector Tec...

Страница 10: ...h lead sulfate To determine if a sulfated battery can be saved follow the instructions in Battery Recondition INTERNAL SHORT CELL BATTERY F01 If the battery being charged has an internal shorted cell the FAULT LED will light If FAULT LED light comes on Vector recommends you take your battery to a certified automotive service center for evaluation BATTERY NOT ACCEPTING A CHARGE Make sure that the c...

Страница 11: ...2 HRS NR NR 10 AMPS 1 8 HRS 3 HRS 4 5 HRS 6 HRS 20 AMPS 1 0 HRS 1 5 HRS 3 0 HRS 3 5 HRS Not recommended for over 18 hours of charging time The times shown in the chart above are approximate and refer to an average automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a dischar...

Страница 12: ...n shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and ...

Отзывы: