TROUBLESHOOTING - FAULT LED LIT

The following conditions may light the FAULT LED:
• Poor connection to battery (or frame).
• Charging too fast - Decrease Charge Rate - Press 2/10/20A button to lower rate.
• Charging too slowly - Battery is large and did not complete charging in 24 hours - Press 2/10/20A to charge at a faster rate.
• Shorted battery cell - Replace battery (F01).
• Open battery Cell - Replace battery (F03).
• Battery sulfated - have battery serviced or replace battery (F03).
• Reverse Polarity LED Lit - disconnect AC then reverse clamp locations on battery and frame.
• Internal over-heat in charger- make sure fan is not blocked (F05).
Try charging another battery, if the FAULT LED does not light, then one of the above problems exists with the initial battery.
Charger will not charge and the fan will not operate if there is a fault. Call Vector Technical Support toll free: (866) 584-
5504.

SULFATED BATTERY (F03)

Batteries left in a discharged state for a long period of time are likely to become "sulfated". Sulfated batteries cannot
accept a high rate of charge since the internal plates are coated with lead sulfate. To determine if a sulfated battery can
be "saved", follow the instructions in Battery Recondition.

INTERNAL SHORT CELL BATTERY (F01)

• If the battery being charged has an internal shorted cell, the FAULT LED will light.
• If FAULT LED light comes on, Vector recommends you take your battery to a certified automotive service center 

for evaluation.

BATTERY NOT ACCEPTING A CHARGE

• Make sure that the charger is plugged into a "live" 110/120VAC outlet and Power LED is lit.
• Unplug charger and check battery connections - ensure that there is a good connection at the battery terminal and/or
vehicle chassis.
• Check the battery for sulfated condition.
• Check that the correct charge rate was selected for the battery being charged.
• Ensure that enough charging time was allowed for-check table in Appendix A (page 11) for approximate 

charging times.

VERY COLD BATTERY

If the battery to be charged is extremely cold (in temperatures less than freezing - 0º C/32º F) it cannot accept a high
rate of charge, so the initial charge rate will be slow. The rate of charge will increase as the battery warms.

NOTE:  

Charger will NOT operate on batteries below 4.0 Volts. If a 12 Volt battery is below 4.0 volts it is probably

shorted, open or sulfated and should be replaced.

WARNING:

DO NOT attempt to charge a frozen battery. 

Содержание VEC1090 A

Страница 1: ... plug rather than cord when disconnecting charger 4 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a Pins on plug of extension cord are the same number size and shape as those of plug on charger b Extension cord is properly wired and in good electrical cond...

Страница 2: ...plug The plug must be plugged into a properly installed and grounded 110 120VAC outlet in accordance with all local codes and ordinances See Figure 1 This battery charger is for use on a 110 120VAC circuit and has a grounding plug that looks like the plug shown in FIGURE 1A If a properly grounded outlet is not available a temporary adapter like the adapter shown in FIGURE 1B may be used to connect...

Страница 3: ...C output clamps only after unplugging AC cord from outlet 2 Never allow clamps to touch each other 3 Attach clamps to battery posts and check for secure connection This will hold clamps securely on terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Position ...

Страница 4: ...urrent is reduced to allow for the maximum proper internal chemical energy transfer Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective battery charge level step down regulation mode Ideal for topping off batteries that have been in storage At the conclusion of Stage 3 the unit will BEEP signaling the co...

Страница 5: ...sing the ON OFF button immediately stops any operating mode and the display shows the circulating pattern Figure 4B Alternator Voltage Check enables a five second check that measures the battery voltage This check is repeated at various electrical load levels and the tests allow the user to determine if the alternator can keep up with the loads It can indicate alternator service may be required Ba...

Страница 6: ... 5 and on the back of charger FIGURE 5 Below the Digital Display are series of four LEDS that light on the following conditions FAULT Lights when any of several faults are detected see F01 through F05 Codes as described above If the Fault LED lights refer to TROUBLESHOOTING for details REV POLARITY Lights when clamps are incorrectly connected to battery terminals CHARGING COMPLETE Indicates Batter...

Страница 7: ...charge rate to appropriate setting 2 10 20A according to battery size POSITIVE GROUNDED VEHICLE Connect the NEGATIVE BLACK charger clamp to the NEGATIVE NEG N ungrounded battery post Then connect the POSITIVE RED battery clamp to the vehicle chassis or engine part away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body d Plug battery charger power cord into ...

Страница 8: ...d to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Whenever a lead acid battery begins to discharge lead sulfate an insulator begins to build up on the battery s internal plates This reduces the ability of the battery to hold a full charge When that battery has an immediate charge most of the lead sulfate is dissolve...

Страница 9: ... any battery fluid that will cause corrosion of the copper clamps Clean the outside case of the charger with a soft cloth and if necessary mild soap solution Do not allow liquid to enter the charger Do not operate when charger is wet Keep the charger cords loosely coiled during storage to prevent damage to the cords Do not use charger if cords or clamps have been damaged in any way call Vector Tec...

Страница 10: ...h lead sulfate To determine if a sulfated battery can be saved follow the instructions in Battery Recondition INTERNAL SHORT CELL BATTERY F01 If the battery being charged has an internal shorted cell the FAULT LED will light If FAULT LED light comes on Vector recommends you take your battery to a certified automotive service center for evaluation BATTERY NOT ACCEPTING A CHARGE Make sure that the c...

Страница 11: ...2 HRS NR NR 10 AMPS 1 8 HRS 3 HRS 4 5 HRS 6 HRS 20 AMPS 1 0 HRS 1 5 HRS 3 0 HRS 3 5 HRS Not recommended for over 18 hours of charging time The times shown in the chart above are approximate and refer to an average automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a dischar...

Страница 12: ...n shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and ...

Отзывы: