background image

7

CAUTION:

 Reverse polarity connection will result in a blown fuse and

may cause permanent damage to the inverter.

Connecting to a Power Source Using Provided Cables:
If the inverter is to be used for extended periods at power  levels above

150 watts, direct connection to the power source is recommended. Use

the provided cables to connect the Power-On-Board™ 400 directly to

the 12 volt power source using the following guidelines:
1. Check to be sure the Power-On-Board™ 400 power switch is turned

off and that no flammable fumes are present.

2. Connect the black cable to the black post marked "(-)" on the back of

the inverter. Connect the battery clip to the negative terminal of the

battery.

3. Connect the red cable to the red post marked "(+)" on the back of the

inverter. Connect the battery clip to the positive terminal of the battery.

4. Check to be sure that all connections between battery clips and

terminals are secure.

Direct Hardwiring to Power Source:
Use #10 AWG wire if the inverter to power source connection is 10 feet

or less. For longer cable lengths use #8 AWG wire. In either case, pro-

tect the positive (+) wire from shorts by installing a 40 Amp fuse or

circuit breaker close to the DC power source (battery) terminal.
1. Check to be sure the inverter’s power switch is turned off and that

no flammable fumes are present.

2. Identify the positive (+) and negative (-) DC power source (battery)

terminals.

3. Install a fuse holder or breaker close to the positive (+) terminal of the

DC source (battery).

4. Connect a length of wire on one side of the fuse holder or circuit

breaker. Connect the other end if the wire to the Positive (+) terminal

of the inverter.

5. Connect a length of wire between he inverter's negative (-) terminal

and the DC power source negative (-) terminal.

6. Connect a short length of wire to the other terminal of the fuse holder

or circuit breaker. Mark it "POSITIVE" or "+".

7. Connect the free end of the fuse or breaker wire to the positive

terminal of the DC power source (battery).

Содержание Power On Board VEC031POB

Страница 1: ...RAGE OF THIS PRODUCT BEFORE USE READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE...

Страница 2: ...g on appliances Multiple outlet power strips with switches and circuit breakers only interrupt power to the hot receptacle terminals The neutral terminals remain powered with respect to the ground ter...

Страница 3: ...equirements 6 3 2 Connection to Power Source 6 8 3 3 Connection to Load 8 3 4 Fuse Replacement 8 3 5 Placement of the Inverter 9 4 OPERATING TIPS 9 10 4 1 Rated Versus Actual Current Draw of Equipment...

Страница 4: ...efits our customers The new design more efficiently cools the power transistors and thereby increases reliability and the life of the product Given proper care and appropriate use your inverter is cov...

Страница 5: ...olts which is the same as standard household power Most AC voltmeters both digital and analog are sensitive to the average value of the waveform rather than the RMS value They are calibrated for RMS v...

Страница 6: ...Power On Board 400 comes equipped with a cigarette lighter plug and battery clip cables for connection to the power source CAUTION Do not use with positive ground electrical systems the majority of m...

Страница 7: ...clips and terminals are secure Direct Hardwiring to Power Source Use 10 AWG wire if the inverter to power source connection is 10 feet or less For longer cable lengths use 8 AWG wire In either case p...

Страница 8: ...ed above Do not connect the Power Inverter to household or RV AC distribution wiring Do not connect the Power Inverter to any AC load circuit in which the neutral conductor is connected to ground eart...

Страница 9: ...periods of time The unit will shut down if the internal temperature exceeds 90 C The unit will restart after it cools SAFE Do not use the inverter near flammable materials or in any locations that may...

Страница 10: ...unexpected shut down of the equipment and will ensure that there is always sufficient battery capacity to start the vehicle s engine The inverter will sound it s alarm when DC voltage drops to 10 6V T...

Страница 11: ...ronic device at this time since the inverter will shut down automatically shortly there after when the battery voltage drops to 10 volts Start your engine to recharge the battery If the low voltage al...

Страница 12: ...D ON TROUBLE INDICATION POSSIBLE CAUSE SUGGESTED REMEDY No AC output DC input below 10 Volts Recharge or replace red LED lit battery No AC output Excessive appliance Reduce load wait for red LED lit l...

Страница 13: ...interference in speaker antenna distant from each other Use shielded antenna cable Connect antenna to amplifier 8 SPECIFICATIONS Maximum Continuous Power 400 watts Surge Capacity Peak Power 800 watts...

Страница 14: ...stage prepaid to Vector Manufacturing Any defective product other than accessories that is returned to Vector Manufacturing within 30 days of the date of purchase will be replaced free of charge If su...

Страница 15: ...keep the original packaging in case you need to ship the unit When returning a product include your name address phone number dated sales receipt or copy and a description of the reason for return and...

Страница 16: ...16 2001 VECTOR MANUFACTURING LTD FT LAUDERDALE FL 33312 MADE IN CHINA...

Отзывы: