Television Interference:
The Vector Power-On-Board™ 400 is shielded to minimize interference

with TV signals. However, in some instances, some interference may still

be visible, particularly with weak TV signals. Try the following corrective

measures:

• Position the inverter as far as possible from the television, the antenna

and the antenna cables. Use an extension cable, if necessary

• Adjust the orientation of the inverter, the antenna cables and the TV

power cord to minimize interference

• Make sure that the antenna feeding the television provides an

adequate ("snow free") signal and that high quality, shielded antenna

cable is used

7.

TROUBLESHOOTING GUIDE:

TABLE 1 - INVERTER POWER SWITCH TURNED ON

TROUBLE/ INDICATION

POSSIBLE CAUSE

SUGGESTED REMEDY

No AC output –

DC input below 10 Volts

Recharge or replace

red LED lit

battery

No AC output –

Excessive appliance

Reduce load-wait for

red LED lit

load-thermal shutdown

inverter to cool. Turn Off,

then turn On

No AC output

Inverter cold

Disconnect load from

inverter. Operate inverter

without load for a few

minutes. Reconnect load.

No AC output –

Inverter fuses open

Open fuse caps in back

Green LED not lit

of inverter. Remove fuses

and replace with same

type and rating

Low battery alarm

Bad connection or wiring

Tighten all DC

sounds continuously

connections

Low battery

Low battery voltage

Recharge battery.

alarm sounds

Remove load from

inverter while recharging

battery

Motorized power tool

Excessive start-up load

Rock the On/Off switch

won’t start

several times. If appliance

does not start, then

appliance will not work

with inverter

Содержание Power On Board VEC031POB

Страница 1: ...RAGE OF THIS PRODUCT BEFORE USE READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE...

Страница 2: ...g on appliances Multiple outlet power strips with switches and circuit breakers only interrupt power to the hot receptacle terminals The neutral terminals remain powered with respect to the ground ter...

Страница 3: ...equirements 6 3 2 Connection to Power Source 6 8 3 3 Connection to Load 8 3 4 Fuse Replacement 8 3 5 Placement of the Inverter 9 4 OPERATING TIPS 9 10 4 1 Rated Versus Actual Current Draw of Equipment...

Страница 4: ...efits our customers The new design more efficiently cools the power transistors and thereby increases reliability and the life of the product Given proper care and appropriate use your inverter is cov...

Страница 5: ...olts which is the same as standard household power Most AC voltmeters both digital and analog are sensitive to the average value of the waveform rather than the RMS value They are calibrated for RMS v...

Страница 6: ...Power On Board 400 comes equipped with a cigarette lighter plug and battery clip cables for connection to the power source CAUTION Do not use with positive ground electrical systems the majority of m...

Страница 7: ...clips and terminals are secure Direct Hardwiring to Power Source Use 10 AWG wire if the inverter to power source connection is 10 feet or less For longer cable lengths use 8 AWG wire In either case p...

Страница 8: ...ed above Do not connect the Power Inverter to household or RV AC distribution wiring Do not connect the Power Inverter to any AC load circuit in which the neutral conductor is connected to ground eart...

Страница 9: ...periods of time The unit will shut down if the internal temperature exceeds 90 C The unit will restart after it cools SAFE Do not use the inverter near flammable materials or in any locations that may...

Страница 10: ...unexpected shut down of the equipment and will ensure that there is always sufficient battery capacity to start the vehicle s engine The inverter will sound it s alarm when DC voltage drops to 10 6V T...

Страница 11: ...ronic device at this time since the inverter will shut down automatically shortly there after when the battery voltage drops to 10 volts Start your engine to recharge the battery If the low voltage al...

Страница 12: ...D ON TROUBLE INDICATION POSSIBLE CAUSE SUGGESTED REMEDY No AC output DC input below 10 Volts Recharge or replace red LED lit battery No AC output Excessive appliance Reduce load wait for red LED lit l...

Страница 13: ...interference in speaker antenna distant from each other Use shielded antenna cable Connect antenna to amplifier 8 SPECIFICATIONS Maximum Continuous Power 400 watts Surge Capacity Peak Power 800 watts...

Страница 14: ...stage prepaid to Vector Manufacturing Any defective product other than accessories that is returned to Vector Manufacturing within 30 days of the date of purchase will be replaced free of charge If su...

Страница 15: ...keep the original packaging in case you need to ship the unit When returning a product include your name address phone number dated sales receipt or copy and a description of the reason for return and...

Страница 16: ...16 2001 VECTOR MANUFACTURING LTD FT LAUDERDALE FL 33312 MADE IN CHINA...

Отзывы: