FUSE REPLACEMENT

If external fuses blow, (or breakers trip), then there is a short or overload

in the DC wiring. Find and fix the problem before replacing the fuses (or

resetting the breaker). After fuse replacement, reconnect the inverter.

This power inverter is equipped with multiple internal fuses. Normally,

these fuses will not blow unless there is a serious problem inside the unit.

Internal fuses are replaceable, however, only electronically knowledgeable

people should attempt fuse replacement.  If the unit is damaged during fuse

replacement, the warranty may be voided. Vector recommends contacting

Vector Technical Support for guidance. Based on experience, it is best to

return the unit to Vector for repair.  Vector Technical Support can be

reached by calling toll free 866-584-5504. You may also contact us by

visiting our [email protected].

10.

SPECIFICATIONS

Output Connection  ..........Dual North American Standard Receptacles

Output Voltage..................................Approx 110 volt AC RMS 60 Hz

Output Current....................................................................3.6 amps

Output Waveform ..................................Modified Sine Wave (filtered)

Input Voltage Range ..........................................10.5 to 15.5 volt DC

Low Voltage Alarm ........................................................10.6 volt DC

Low Voltage Shutdown....................................................10.0 volt DC

No Load Input Current ........................................................0.4 amps

Input Fuses ............................................................................Internal

Input Cables: ..........................One 12 volt DC Plug (up to 175 Watts)

Battery Clip Cable....................................................(up to 400 watts)

Additional Protection ..........................Overload, Over volt, Over temp

Weight....................................................................1.45 Lbs (.66 kg)

Length  ..................................................................6.0 in. (15.24 cm)

Width  ..................................................................6.0 in. (15.24 cm)

Height  ..................................................................2.0 in.  (5.08 cm)

11. 

WARRANTY

2 YEAR LIMITED WARRANTY PROGRAM

This limited warranty program is the only one that applies to this product, and it sets

forth all the responsibilities of Vector Manufacturing, Ltd., regarding this product. There

are no other warranties, other than those described herein.

This Vector Manufacturing, Ltd. product is warranted, to the original 

Содержание Maxx SST VEC024

Страница 1: ...AD AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28TH...

Страница 2: ...C plug connections and ring terminal connections 4 This is not a toy keep away from children CAUTIONS 1 Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks...

Страница 3: ...ION 6 4 1 Power Source Requirements 6 7 4 2 Connection to Power Source 7 8 4 3 Connection to Load 8 9 4 4 Placement of Inverter 9 5 OPERATING TIPS 10 5 1 Rated Versus Actual Current Draw of Equipment...

Страница 4: ...start up currents from large inductive loads could shut down the inverter Three major features are incorporated in SST First gradual voltage ramp upduring inverter start up This eliminates failed col...

Страница 5: ...t converts the high voltage DC into 110 volts 60 Hz AC The DC to DC converter stage uses modern high frequency power conversion techniques that have replaced the bulky transformers found in less techn...

Страница 6: ...voltage under the assumption that the waveform measured will be a pure sine wave These meters will not read the RMS voltage of a modified sine wave correctly They will read about 20 to 30 volts low wh...

Страница 7: ...volt DC plug firmly into the 12 volt DC socket of a vehicle or other DC power source CAUTION Connect directly to power source when operating above 175 watts NOTE Most automobile 12 volt DC circuits us...

Страница 8: ...he positive terminal of the DC source battery 4 Connect a length of wire on one side of the fuse holder or circuit breaker Connect the other end if the wire to the positive terminal of the inverter 5...

Страница 9: ...o not use the inverter to recharge items that q can be plugged directly into an AC receptacle This problem does not occur with the majority of battery operated equipment Most of these devices use a se...

Страница 10: ...nverter can be manually restarted by reseting the on off switch Resistive loads are the easiest for the MAXX 400 SST to run However larger resistive loads such as electric stoves or heaters usually re...

Страница 11: ...SST monitors the following potentially hazardous conditions LOW BATTERY VOLTAGE This condition is not harmful to the inverter but could damage the power source An audible alarm will sound when input...

Страница 12: ...emit a buzzing sound from their speakers when operated from the MAXX 400 SST power inverter This occurs because the power supply in the electronic device does not adequately filter the modified sine w...

Страница 13: ...alarm Bad connection or wiring Tighten all DC sounds continuously connections Low battery Low battery voltage Recharge battery alarm sounds Remove load from inverter while recharging battery Motorize...

Страница 14: ...You may also contact us by visiting our website www vectormfg com 10 SPECIFICATIONS Output Connection Dual North American Standard Receptacles Output Voltage Approx 110 volt AC RMS 60 Hz Output Curre...

Страница 15: ...oes not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight acciden...

Страница 16: ...2004 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA VECTOR MANUFACTURING LTD...

Отзывы: