background image

8

8

3.  Connect the red cable to the red post marked “(+)” on the back of the

inverter. Connect the battery clip to the positive terminal of the battery.

4.   Check to be sure that all connections between battery clips and  

terminals are secure.

Direct Hardwiring to Power Source:

Use #10 AWG wire if the inverter to power source connection is 12 feet or

less. For longer cable lengths use #8 AWG wire. In either case, protect the

positive (+) wire from shorts by installing a 50 Amp fuse or circuit breaker

close to the DC power source (battery) terminal.

1.

Check to be sure the inverter’s power switch is turned off and that no

flammable fumes are present.

2.

Identify the positive (+) and negative (-) DC power source (battery) 

terminals.

3.  Install a fuse holder or breaker close to the positive (+) terminal of the

DC source (battery).

4.

Connect a length of wire on one side of the fuse holder or circuit breaker.

Connect the other end if the wire to the positive (+) terminal of the inverter.

5.

Connect a length of wire between the inverter’s negative (-) terminal

and the DC power source negative (-) terminal.

6.

Connect a short length of wire to the other terminal of the fuse holder

or circuit breaker. Mark it “POSITIVE” or “+”.

7.

Connect the free end of the fuse or breaker wire to the positive 

terminal of the DC power source (battery).

8.  Insert a 50 amp fuse in the fuse holder.

9.

Test the inverter by turning it on and plugging in a 100 watt lamp or

equipment.

10. If the inverter is not properly operating, then refer to the trouble-

shooting sections of this manual.

CAUTION:

Loose connectors may cause overheated wires and melted 

insulation. Check to make sure you have not reversed the polarity. 

Damage due to reversed polarity is not covered by our warranty.

Содержание Maxx SST VEC024

Страница 1: ...AD AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28TH...

Страница 2: ...C plug connections and ring terminal connections 4 This is not a toy keep away from children CAUTIONS 1 Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks...

Страница 3: ...ION 6 4 1 Power Source Requirements 6 7 4 2 Connection to Power Source 7 8 4 3 Connection to Load 8 9 4 4 Placement of Inverter 9 5 OPERATING TIPS 10 5 1 Rated Versus Actual Current Draw of Equipment...

Страница 4: ...start up currents from large inductive loads could shut down the inverter Three major features are incorporated in SST First gradual voltage ramp upduring inverter start up This eliminates failed col...

Страница 5: ...t converts the high voltage DC into 110 volts 60 Hz AC The DC to DC converter stage uses modern high frequency power conversion techniques that have replaced the bulky transformers found in less techn...

Страница 6: ...voltage under the assumption that the waveform measured will be a pure sine wave These meters will not read the RMS voltage of a modified sine wave correctly They will read about 20 to 30 volts low wh...

Страница 7: ...volt DC plug firmly into the 12 volt DC socket of a vehicle or other DC power source CAUTION Connect directly to power source when operating above 175 watts NOTE Most automobile 12 volt DC circuits us...

Страница 8: ...he positive terminal of the DC source battery 4 Connect a length of wire on one side of the fuse holder or circuit breaker Connect the other end if the wire to the positive terminal of the inverter 5...

Страница 9: ...o not use the inverter to recharge items that q can be plugged directly into an AC receptacle This problem does not occur with the majority of battery operated equipment Most of these devices use a se...

Страница 10: ...nverter can be manually restarted by reseting the on off switch Resistive loads are the easiest for the MAXX 400 SST to run However larger resistive loads such as electric stoves or heaters usually re...

Страница 11: ...SST monitors the following potentially hazardous conditions LOW BATTERY VOLTAGE This condition is not harmful to the inverter but could damage the power source An audible alarm will sound when input...

Страница 12: ...emit a buzzing sound from their speakers when operated from the MAXX 400 SST power inverter This occurs because the power supply in the electronic device does not adequately filter the modified sine w...

Страница 13: ...alarm Bad connection or wiring Tighten all DC sounds continuously connections Low battery Low battery voltage Recharge battery alarm sounds Remove load from inverter while recharging battery Motorize...

Страница 14: ...You may also contact us by visiting our website www vectormfg com 10 SPECIFICATIONS Output Connection Dual North American Standard Receptacles Output Voltage Approx 110 volt AC RMS 60 Hz Output Curre...

Страница 15: ...oes not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight acciden...

Страница 16: ...2004 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA VECTOR MANUFACTURING LTD...