SELV Products

All SELV (safety extra low voltage) products must
be installed to conform to IEC 60364.
• Connection between the fan and the mains 

supply must be by means of a safety isolating 
transformer of the appropriate power rating

• The transformer should be connected to the 

mains supply via a double pole safety switch 
with a contact opening of at least 3mm

• The transformer will operate only one fan
• The transformer must 

not

be installed in

Zones 1 or 2, but 

should 

be installed as close

as possible to the fan within Zone 3

• The cable used to connect the transformer to 

the fan must be Class II, with a section area of
at least 1.5mm

2

and a maximum length of 10m

• If the fan is a humidity control model, it must 

be installed using the transformer supplied for 
that product. 

The ES1003 fans are 

designed to run con-

tinuously at one of 2 lower speeds fixed at
installation using the jumper switch.  The
SELV models have 3 pins on the jumper
switch (rather than 2 as on the 230v models)
and are supplied ready for Speed 1 - lower
speed.  Installer can change to Speed  2 if
required.  The user can boost the fan speed
to its maximum performance by using cord
or remote switch (when installing with
remote switch, pullcord switch must be left
in "off" position and cord removed).

Содержание eSmile

Страница 1: ...continuous running with or without filter humidity control SELV low voltage 3 speed continuous running humidity control for all domestic wet rooms for walls or ceilings IPX4 IPX7 쓑 The Carbon Friendly Fan Installation and Operating Instructions ...

Страница 2: ...ct before doing this Do not leave packing material within the reach of children or unskilled people To dispose of the packaging and the appliance at the end of its useful life refer to the recycling norms in force The use of any electrical product requires compliance with some basic rules which are listed below do not touch it with wet or damp parts of the body e g hands feet this appliance can be...

Страница 3: ...replacement to ensure maxi mum effectiveness If the product is sited in a room containing a fuel burning appliance which is not of the bal anced flue type the installer must ensure that air replacement is adequate both for the fan and the fuel burning appliance The product must not be used as an activator for water heaters stoves etc The product must not exhaust into ducts designed to evacuate fum...

Страница 4: ...ws the fan to run at low speed for its over run period The humidistat is adjustable from 40 to 90 relatve humidity ES1003CLV 12v SELV version of ES1003 ES100H2CLV 12v SELV version of ES100H2C 4 INSTALLATION ...

Страница 5: ...5 ...

Страница 6: ...8 gasket included for ceiling installation Fig 9 screw fan to wall Figs 10 ll make electrical connection using cable clamp Figs A Wiring diagrams follow NB this fan is double insulated and does not need to be earthed N B This fan is NOT suitable for use with a Gravity Grille It should be installed using either a Cowl or Fixed Grille Fig 12 Replace front cover ES1003 JUMPER SWITCH 230v models The E...

Страница 7: ...003CF 3 Speed with Filter Cord removed ES100H2C Humidity Control Cord removed 7 WIRING DIAGRAMS VIA REMOTE ILLUMINATED SWITCH ES1003 3 Speed with Cord removed ES1003CF 3 Speed with Filter Cord removed ES100H2C Humidity Control Cord removed N B When installing fans via a remote switch pullcord switch must be left in off position and the cord removed ...

Страница 8: ...ed in Zones 1 or 2 but should be installed as close as possible to the fan within Zone 3 The cable used to connect the transformer to the fan must be Class II with a section area of at least 1 5mm2 and a maximum length of 10m If the fan is a humidity control model it must be installed using the transformer supplied for that product The ES1003 fans are designed to run con tinuously at one of 2 lowe...

Страница 9: ...n the relative humidity reaches the pre set level and will continue to operate at this speed until the humidity has been dispersed The user can use the cord to operate the fan at its higher speed or to boost the fan speed if it is already running Pulling the cord again will revert the fan to its lower speed and it will continue to run either until the humidity has been removed or the fan has compl...

Страница 10: ...s Fig 14 The humidistat can be adjusted Fig 15 between 40 and 90 relative humidity Turn clockwise to decrease sensitivity and set at a higher level of relative humidity The timer is adjustable between 3 and 25 min utes Turn the trimmer Fig 16 clockwise to increase the overrun time or anti clockwise to decrease it ADJUSTMENT OF TRIMMERS ...

Страница 11: ...fied technician before reassembling the fan NOTE The motor does not require lubrication as it is maintenance free sealed for life type DISMANTLING RECYCLING This product has been designed and constructed using high quality materials and components that can be recycled or re used Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494...

Отзывы: