Vectaire eSmile Скачать руководство пользователя страница 2

"E-Smile” - THE POWERFUL CARBON FRIENDLY FANS
INSTALLATION and OPERATING INSTRUCTIONS

THIS LEAFLET MUST BE AVAILABLE TO THE USER

The  product  you  have  purchased  is  an  extractor
fan for exhausting directly outside or through medi-
um  lengths  of  ducting  and  is  suitable  for  wall  or
ceiling  installation.  To  ensure  optimum  operation
and guarantee a long life, please read this manual
carefully.    It  explains  how  to  install  correctly,  use
and  maintain  the  product  properly.    Following
these  instructions  will  ensure  the  reliability  of  the
product and extend its working life.  

The manufacturer will not be held responsible
and will not accept any responsibility for dam-
age  caused  to  persons  or  things  due  to
improper use with reference to the precautions
outlined in this leaflet.

The  product,  constructed  using  state  of  the  art
technology,  complies  with  current  standards
regarding  electrical  equipment.  It  conforms  with
the  EMC  2014/30/EU  European  Directive  regard-
ing  radio  interference  suppression  and  electro-
magnetic compatibility.

WARNING:  Serious  injury  or  death  could  result  if
these instructions are not carefully followed

Do not use this product for any purpose other 
than that for which it was designed.

Remove the product from its packaging and make
sure that it has not been damaged.  If in doubt,
contact the supplier, authorised dealer, service 
centre or manufacturer to check that the prod
uct will still operate correctly.  Do not  attempt 
to use or repair the product before doing this.

Do not leave packing material within the reach 
of children or unskilled people.  To dispose of 
the packaging and the appliance at the end of its
useful life refer to the recycling norms in force.  

The use of any electrical product requires 
compliance with some basic rules which are 
listed below:
- do not touch it with wet or damp parts of the 

body (e.g hands, feet).

- this appliance can be used by children aged 

from 8 years and above and persons with 
reduced physical, sensory or mental capabili-
ties or lack of experience and knowledge if 
they have been given supervision or instruc
tion concerning use of the appliance in a 
safe way and understand the hazards in-
volved. Children shall not play with the appli
ance. Cleaning and user maintenance shall 
not be done by children without supervision.

• The product should be connected to the mains 

electricity supply or electrical outlet only if:
- the electrical voltage and frequency corre-

spond to those shown on the rating label.

- the capacity of the electricity supply is suffi-

cient to operate the product at its maximum 
power.

- suitable electrical protection must be provid-

ed for the product to be installed.

• The electrical supply to which the fan is con-

nected must comply with all existing regula-
tions. All installations must comply with current 
IEE wiring regulations.

• Before maintenance or cleaning is carried out, 

the product must be switched off and discon-
nected  from the mains electricity supply.

• If a fault, malfunction or anomaly of any type 

occurs, the fan should be isolated (switching it 
off and disconnecting it from the mains electric
ity supply) and advice sought  from qualified 
personnel.

2

Содержание eSmile

Страница 1: ...continuous running with or without filter humidity control SELV low voltage 3 speed continuous running humidity control for all domestic wet rooms for walls or ceilings IPX4 IPX7 쓑 The Carbon Friendly Fan Installation and Operating Instructions ...

Страница 2: ...ct before doing this Do not leave packing material within the reach of children or unskilled people To dispose of the packaging and the appliance at the end of its useful life refer to the recycling norms in force The use of any electrical product requires compliance with some basic rules which are listed below do not touch it with wet or damp parts of the body e g hands feet this appliance can be...

Страница 3: ...replacement to ensure maxi mum effectiveness If the product is sited in a room containing a fuel burning appliance which is not of the bal anced flue type the installer must ensure that air replacement is adequate both for the fan and the fuel burning appliance The product must not be used as an activator for water heaters stoves etc The product must not exhaust into ducts designed to evacuate fum...

Страница 4: ...ws the fan to run at low speed for its over run period The humidistat is adjustable from 40 to 90 relatve humidity ES1003CLV 12v SELV version of ES1003 ES100H2CLV 12v SELV version of ES100H2C 4 INSTALLATION ...

Страница 5: ...5 ...

Страница 6: ...8 gasket included for ceiling installation Fig 9 screw fan to wall Figs 10 ll make electrical connection using cable clamp Figs A Wiring diagrams follow NB this fan is double insulated and does not need to be earthed N B This fan is NOT suitable for use with a Gravity Grille It should be installed using either a Cowl or Fixed Grille Fig 12 Replace front cover ES1003 JUMPER SWITCH 230v models The E...

Страница 7: ...003CF 3 Speed with Filter Cord removed ES100H2C Humidity Control Cord removed 7 WIRING DIAGRAMS VIA REMOTE ILLUMINATED SWITCH ES1003 3 Speed with Cord removed ES1003CF 3 Speed with Filter Cord removed ES100H2C Humidity Control Cord removed N B When installing fans via a remote switch pullcord switch must be left in off position and the cord removed ...

Страница 8: ...ed in Zones 1 or 2 but should be installed as close as possible to the fan within Zone 3 The cable used to connect the transformer to the fan must be Class II with a section area of at least 1 5mm2 and a maximum length of 10m If the fan is a humidity control model it must be installed using the transformer supplied for that product The ES1003 fans are designed to run con tinuously at one of 2 lowe...

Страница 9: ...n the relative humidity reaches the pre set level and will continue to operate at this speed until the humidity has been dispersed The user can use the cord to operate the fan at its higher speed or to boost the fan speed if it is already running Pulling the cord again will revert the fan to its lower speed and it will continue to run either until the humidity has been removed or the fan has compl...

Страница 10: ...s Fig 14 The humidistat can be adjusted Fig 15 between 40 and 90 relative humidity Turn clockwise to decrease sensitivity and set at a higher level of relative humidity The timer is adjustable between 3 and 25 min utes Turn the trimmer Fig 16 clockwise to increase the overrun time or anti clockwise to decrease it ADJUSTMENT OF TRIMMERS ...

Страница 11: ...fied technician before reassembling the fan NOTE The motor does not require lubrication as it is maintenance free sealed for life type DISMANTLING RECYCLING This product has been designed and constructed using high quality materials and components that can be recycled or re used Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494...