46
©Vecow SPC-5000 User Manual
GETTING TO KNOW YOUR SPC-5000
2.6.2 Ignition Control Wiring
To activate ignition control, you need to provide IGN signal via the 3-pin
pluggable terminal block locates in the back panel. Please find below the
general wiring configuration
For testing purpose, you can refer to the picture blow to simulate ignition signal
input controlled by a latching switch.
Note :
1.
DC power source and IGN share the same ground.
2.
EMBC-3000 supports 9V to 48V wide range DC power input in ATX/AT mode. In
Ignition mode, the input voltage is fixed to 12V/24V for car battery scenario.
3.
For proper ignition control, the power button setting should be "Power Down" mode.
In Windows for
example, you need
to set "When I press
the power button" to
Shut down.
Pin No.
Definition
1
Ignition (IGN)
2
SW+
3
SW-
IGN
IGN
V+
V-
Содержание SPC-5000
Страница 55: ...48 Vecow SPC 5000 User Manual SYSTEM SETUP Step 4 Remove one F M3x4 screw Step 5 Open bottom Cover...
Страница 62: ...55 Vecow SPC 5000 User Manual SYSTEM SETUP 3 6 2 Installing SPC 5200 SSD HDD Step 1 Fasten 4 M3 screw...
Страница 64: ...57 Vecow SPC 5000 User Manual SYSTEM SETUP 3 8 3 SPC 5200 Fasten four M3 screws 53 2426206 80B...