background image

82

BIOS AND DRIVER 

©Vecow EVS-2000 User Manual 

4.3.7  IT8786 Super IO Configuration

Figure 4-3-7 : IT8786 Super IO Settings

4.3.7.1  Serial Port X Configuration

Serial Port 1 to port 4 Configuration

Options for Serial Port 1 to Serial Port 4.
Entering the corresponding Port option then end user can change the settings 

such as I/O resource and UART mode (High Speed Serial Port is Port 1 only).

Figure 4-3-7-1 : Serial Port X Configuration

Содержание EVS-2000 Series

Страница 1: ...USER Manual USER Manual 1 3 0 Edition 20210311 EVS 2000 10thGen Intel Xeon Core i9 i7 i5 i3FanlessAIComputingSystemwith NVIDIA AMD MXM GPU Graphics High Performance Expandable...

Страница 2: ...ii Version Date Page Description Remark 1 00 01 28 2021 All Official Release 1 10 01 29 2021 29 42 Update 1 20 02 25 2021 8 10 Update 1 30 03 11 2021 4 6 8 10 20 Update Record of Revision...

Страница 3: ...energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is like...

Страница 4: ...2 Isolated DIO With System Fan EVS 2001F EVS 2000 2 GigE LAN 1 PCI 6 USB 3 2 3 COM 2 SIM 32 Isolated DIO With System Fan Order Information CPU List Series CPU Cores GHz TDP W ECC RAM Intel Xeon W 1290...

Страница 5: ...ture 30 C to 70 C PWS 480W WT 480W 24V 90V AC to 305V AC Power Supply Wide Temp IP65 VESA Mount VESA Mounting Kit DIN RAIL DIN Rail Kit and VESA Mounting Kit Rack Mount 2U Rackmount Kit TMK2 20P 100 T...

Страница 6: ...s of EVS 2000F 12 CHAPTER 2 GETTING TO KNOW YOUR EVS 2000 13 2 1 Packing List 13 2 1 1 Packing List of EVS 2000 13 2 1 2 Packing List of EVS 2000F 14 2 2 Front Panel I O Functions 15 2 3 Rear Panel I...

Страница 7: ...73 CHAPTER 4 BIOS AND DRIVER 76 4 1 BIOS Settings 76 4 2 Main 77 4 3 Advanced 77 4 4 Chipset 90 4 5 Security 96 4 6 Boot 98 4 7 Save Exit 99 APPENDIX A Isolated DIO Guide 100 APPENDIX B Software Funct...

Страница 8: ...olution delivering astounding visual computing performance and accelerating compact specific applications Vecow EVS 2000 Series offers a wide range of I O connectivity including 2 GigE LAN 6 USB 3 COM...

Страница 9: ...roductivity by advanced NVIDIA CUDA cores Fanless 25 C to 55 C Operating Temperature Nano SIM Sockets for 5G WiFi 4G 3G LTE GPRS UMTS Expansion 1 M 2 Key B 1 M 2 Key E 1 Mini PCIe optional SUMIT A B S...

Страница 10: ...ion Mini PCIe 1 Mini PCIe Socket for PCIe USB SIM Card mSATA PCI PCIe 1 PCIe x4 Slot M 2 1 M 2 Key B Socket 3042 3052 1 M 2 Key E Socket 2230 SUMIT A B 2 SUMIT Slot Optional Graphics Graphics Processo...

Страница 11: ...t 1 to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control when CPU overheats Software Support OS Windows 10 Linux Mechan...

Страница 12: ...Ie 1 Mini PCIe Socket for PCIe USB SIM Card mSATA PCI PCIe 1 PCI Slot M 2 1 M 2 Key B Socket 3042 3052 1 M 2 Key E Socket 2230 SUMIT A B 2 SUMIT Slot Optional Graphics Graphics Processor Intel UHD Gra...

Страница 13: ...to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control when CPU overheats Software Support OS Windows 10 Linux Mechanical...

Страница 14: ...ini PCIe Socket for PCIe USB SIM Card mSATA PCI PCIe 1 PCIe x4 Slot M 2 1 M 2 Key B Socket 3042 3052 1 M 2 Key E Socket 2230 SUMIT A B 2 SUMIT Slot Optional Graphics Graphics Processor Intel UHD Graph...

Страница 15: ...hdog Timer Reset 1 to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control when CPU overheats Software Support OS Windows...

Страница 16: ...Mini PCIe Socket for PCIe USB SIM Card mSATA PCI PCIe 1 PCI Slot M 2 1 M 2 Key B Socket 3042 3052 1 M 2 Key E Socket 2230 SUMIT A B 2 SUMIT Slot Optional Graphics Graphics Processor Intel UHD Graphic...

Страница 17: ...chdog Timer Reset 1 to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control when CPU overheats Software Support OS Windows...

Страница 18: ...5W 16M Up to 4 4GHz Y W 1250TE 6 35W 12M Up to 3 8GHz Y Intel Core i9 10900E 10 65W 20M Up to 4 7GHz NA i9 10900TE 10 35W 20M Up to 4 5GHz NA i7 10700E 8 65W 16M Up to 4 5GHz NA i7 10700TE 8 35W 16M U...

Страница 19: ...mensions of EVS 2000 5 0 0 20 20 0 0 79 R4 5 0 18 A 317 0 12 48 302 0 11 89 280 0 11 02 155 0 6 10 215 0 8 46 79 1 3 11 Unit mm inch 1 5 2 Dimensions of EVS 2000F 86 5 3 41 5 0 0 20 20 0 0 79 R4 5 0 1...

Страница 20: ...ccessory box which contains Vecow Drivers Utilities DVD 1 Item Description Outlook Usage P N Qty 1 PHILLPIS M2 5x6L Ni Mini PCIe module card 53 2426906 30B 1 2 PHILLPIS M3x4L Ni Ny M 2 53 2426204 80B...

Страница 21: ...ntains Vecow Drivers Utilities DVD 1 Item Description Outlook Usage P N Qty 1 PHILLPIS M2 5x6L Ni Mini PCIe module card 53 2426906 30B 1 2 PHILLPIS M3x4L Ni Ny M 2 53 2426204 80B 4 3 Terminal block 3...

Страница 22: ...r status S0 S3 and S5 More detail LED indications are listed as follows LED Color Power Status System Status Solid Blue S0 System working Solid Orange S3 S5 Suspend to RAM System off with standby powe...

Страница 23: ...tem without power off the system Press the Reset Switch for a few seconds and then reset will be enabled Micro SD SIM1 SIM2 DP DP LAN 2 LAN 1 DVI D VGA SIM1 SIM2 mapping table as below table SIM Slot...

Страница 24: ...ff Storage status function or not Twinkling Data transferring Micro SD SIM1 SIM2 DP DP LAN 2 LAN 1 DVI D VGA 2 2 5 DVI D Connector Micro SD SIM1 SIM2 DP DP LAN 2 LAN 1 DVI D VGA The DVI D connector on...

Страница 25: ...Signal 10 Ground 3 Blue Color Signal 11 NC 4 NC 12 DDC DATA 5 Ground 13 H Sync 6 VGA Detect 14 V Sync 7 Ground 15 DDC CLK 8 Ground 5 1 15 11 10 6 2 2 6 VGA Connector 2 2 7 DisplayPort Micro SD SIM1 S...

Страница 26: ...10 100 1000 Mbps Ethernet connections in the front side LAN 1 is powered by Intel i219 Ethernet Phy and LAN 2 is powered by Intel I210 Ethernet engine When both LAN 1 and LAN 2 work at normal status i...

Страница 27: ...ED will keep twinkling off when Ethernet data packets are being transmitted received LED Location LED Color 10Mbps 100Mbps 1000Mbps Right Green Orange Off Solid Green Solid Orange Left Yellow Flash Gr...

Страница 28: ...ro sd port are listed as follows Pin No Description Pin No Description 1 SD_DATA2 6 GND 2 SD_DATA3 7 SD_DATA0 3 SD_CMD 8 SD_DATA1 4 SD_PWR V3 3 9 SD_WP 5 SD_CLK 10 SD_DET 2 2 12 SSD HDD Tray There are...

Страница 29: ...efine is as below table Pin No Definition 1 V 2 V 3 Chassis Ground 2 3 2 Remote Power On Off Switch Ignition It is a 2 pin power on or power off switch through Phoenix Contact terminal block You could...

Страница 30: ...tion COM 1 COM 2 COM 3 COM 4 RS 232 RS 422 5 wire RS 422 9 wire RS 485 RS 485 w z auto flow control The rear i Io D SUB connector pin assignments are listed in the following table Serial Port Pin No R...

Страница 31: ...YOUR EVS 2000 Vecow EVS 2000 User Manual COM3 COM4 MB connector pin out CN Pin No Signal Name Pin No Signal Name COM1 to COM4 1 NC 6 TXD 2 GND 7 RTS 3 RI 8 RXD 4 DTR 9 DSR 5 CTS 10 DCD 1 22 21 2 1 CO...

Страница 32: ...ant with the requirements of Super Speed SS High Speed HS Full Speed FS and Low Speed LS 2 3 5 DisplayPort Onboard Display Port supports auxiliary channel dual mode and the connection supports up to 7...

Страница 33: ...T14 DIO2_GPO6 8 EXT_IN15 DIO2_GPI7 18 EXT_OUT15 DIO2_GPO7 9 VDI_COM1 19 GND_ISO_ DIO1 10 GND_ISO_ DIO1 20 VDIO_EXT1 6 48V Input There is a 32 bit 16 bit DI 16 bit DO with 2 DIO connectors in the rear...

Страница 34: ...7 EXT_IN6 SIO_GPI86 17 EXT_OUT6 SIO_GPO76 8 EXT_IN7 SIO_GPI87 18 EXT_OUT7 SIO_GPO77 9 VDI_COM 19 GND_ISO_ DIO 10 GND_ISO_ DIO 20 VDIO_EXT 6 48V Input DI Reference Circuit Sink Mode NPN V V Power Suppl...

Страница 35: ...28 GETTING TO KNOW YOUR EVS 2000 Vecow EVS 2000 User Manual 2 3 7 Add Card Optional for PCIe x4 FHHL add on card or PCI card...

Страница 36: ...2000 Main Board with Connector Location DEBUG1 1 22 21 2 1 COM1 COM2 COM3 COM4 JRI_PWR1 JRI_PWR2 M2M_CN1 M2B_CN2 MPCIE1 M2B_CN1 SATA2 SATA1 M2E_CN1 JIGNMODE1 SW2 J2 JP3 JP4 JCMOS1 JUSBPWR1 SODIMM2 SOD...

Страница 37: ...as hard drive LED indicator reset button power LED indicator and power on off button which already can be accessed by front panel and top panel The pin outs of miscellaneous port are listed in follow...

Страница 38: ...l onboard supporting DDR4 2400 2133 and up to 64GB Each channel 16GB Slot Description SODIMM1 DDR4 Channel A SODIMM2 DDR4 Channel B 2 4 4 BIOS Socket CN1 If the BIOS need to be changed please contact...

Страница 39: ...ffort and smaller required space Pin No Description Pin No Description 1 Ground 5 RX DN 2 TX DP 6 RX DP 3 TX DN 7 Ground 4 Ground 1 22 21 2 1 SATA2 SATA1 2 4 6 SATA Power Header HDDpPWR1 HDD_PWR2 Stan...

Страница 40: ...der is through by LPC interface and pins define are listed in the following table Pin No Pin Name Pin No Pin Name 1 3 3V 6 AD3 2 SERIRQ 7 FRAME 3 AD0 8 24M CLCOK 4 AD1 9 RESET 5 AD2 10 GND DEBUG1 1 22...

Страница 41: ...12 SPI_MOSI 13 Reserved 14 SPI_CLK 15 5V 16 SPI_CS10 17 USB_3 18 SPI_CS1 19 USB_3 20 Reserved 21 5V 22 LPC_DRQ1 23 USB_2 24 LPC_AD0 25 USB_2 26 LPC_AD1 27 5V 28 LPC_AD2 29 USB_1 30 LPC_AD3 31 USB_1 3...

Страница 42: ...CPRSNT C_PE_CLKREQ 14 GND 15 C_PET_P0 16 C_PER_P0 17 C_PET_N0 18 C_PER_N0 19 GND 20 GND 21 C_PET_P1 22 C_PER_P1 23 C_PET_N1 24 C_PER_N1 25 GND 26 GND 27 C_PET_P2 28 C_PER_P2 29 C_PET_N2 30 C_PER_N2 31...

Страница 43: ...ed 52 3 3Vaux 49 Reserved 50 GND 47 Reserved 48 1 5V 45 Reserved 46 Reserved 43 GND 44 Reserved 41 3 3Vaux 42 Reserved 39 3 3Vaux 40 GND 37 GND 38 USB_D 35 GND 36 USB_D 33 PETp0 34 GND 31 PETn0 32 SMB...

Страница 44: ...hium battery It is recommended that you not replace the lithium battery on your own If the battery needs to be changed please contact the Vecow RMA service team Pin No Description Pin No Description 1...

Страница 45: ...signments of CPU_FAN1 and MXM_FAN1 are listed in the following table Pin No Description Pin No Description 1 GND 2 12V 2A max 3 Fan speed sensor 4 Fan PWM MXA_FAN1 CPU_FAN1 2 4 12 MXM POWER MXMPWR1 Th...

Страница 46: ...000 provides 4 serial ports COM1 COM4 headers for internal COM port cable and the pin define are listed in the following table COM3 Pin No Description Pin No Description 1 NC 6 TXD 2 Ground 7 RTS 3 RI...

Страница 47: ...ard types include 2230 Pin Out Pin No Description Pin No Description 75 GND 74 V3 3_AUX 73 NC 72 V3 3_AUX 71 NC 70 NC 69 GND 68 PCIE_CLK_REQ 67 NC 66 NC 65 NC 64 M2E_REFCLK 63 GND 62 SMB_ALERT 61 NC 6...

Страница 48: ...20 NC 17 NC 18 GND 15 NC 16 LED2 13 GND 14 NC 11 NC 12 NC 9 NC 10 NC 7 GND 8 NC 5 USB 6 LED1 3 USB 4 V3 3_AUX 1 GND 2 V3 3_AUX 2 4 15 M 2 KEY M M2M_CN1 M 2 KEY M PCIe x4 SATA Support M 2 key M connect...

Страница 49: ...cow EVS 2000 User Manual 2 4 16 M 2 KEY B M2B_CN1 M2B_CN2 M 2 KEY B USB 3 0 USB 2 0 Support default PCIe x2 BIOS option M2B_CN1 Module card types include 3042 3052 and M2B_CN2 Module card types includ...

Страница 50: ...by setting jumpers A jumper is a metal bridge used to close an electric circuit It consists of two metal pins and a small metal clip often protected by a plastic cover that slides over the pins to co...

Страница 51: ...to match the needs of your application by DIP switch As below show the DIP switch on and off 2 5 2 USB Power Jumper JUSBPWR1 Jumper Setting Function JUSBPWR1 1 2 Supported Wake Up Default 2 3 Non Wak...

Страница 52: ...2 12V 1A max 3 4 5 6 COM1 RI Default 7 8 12V 1A max 9 10 11 12 COM2 RI Default 2 5 3 COM Port RI Pin Select JRI_PWR1 JRIPWR2 Pin Header Pin No Description JRI_PWR2 1 2 12V 1A max 3 4 5 6 COM3 RI Defau...

Страница 53: ...cow EVS 2000 User Manual Jumper Setting Function JP4 1 3 MXM VGA Enable 3 5 MXM VGA Disable 2 5 4 MXM VGA Disable JP4 1 22 21 2 1 JP4 Jumper Setting Function JCMOS1 1 2 Normal Default 2 3 Clear CMOS 2...

Страница 54: ...ble security measures defined in the Flash Descriptor Default 2 3 Disable Flash Descriptor Security override 2 5 6 JHDA_SDO1 1 22 21 2 1 JHDA_SDO1 2 5 7 Ignition Mode JIGNMODE1 1 22 21 2 1 JIGNMODE1 J...

Страница 55: ...itors the ignition signal and turns on off the system according to pre defined on off delay period 2 6 1 Adjust Ignition Control Modes EVS 2000 series provides 16 modes of different power on off delay...

Страница 56: ...30 seconds 6 5 seconds 60 seconds 7 5 seconds 90 seconds 8 5 seconds 30 minutes 9 5 seconds 1 hour A 10 seconds 2 hours B 10 seconds 4 hours C 10 seconds 6 hours D 10 seconds 8 hours E 10 seconds 12...

Страница 57: ...o the picture blow to simulate ignition signal input controlled by a latching switch Note 1 DC power source and IGN share the same ground 2 EVS 2000 supports 9V to 50V wide range DC power input in ATX...

Страница 58: ...51 SYSTEM SETUP 3 SYSTEM SETUP 3 1 How to Open Your EVS 2000 Step 1 Remove one F M3x4L screw Step 2 Remove one F M3x4L Red and trigger and open PCI cover Blue...

Страница 59: ...52 SYSTEM SETUP Vecow EVS 2000 User Manual Step 3 Remove six F M3x4L screws Step 4 Take off the bottom cover...

Страница 60: ...53 SYSTEM SETUP Step 5 Finish...

Страница 61: ...54 SYSTEM SETUP Vecow EVS 2000 User Manual 3 2 Installing CPU Step 1 Open the Heat Sink EVS 2000 Step 1 1 Remove six I M3x6L screws EVS 2000F Step 1 1 Remove four F M3x4L screws...

Страница 62: ...55 SYSTEM SETUP Step 1 2 Remove fan module header Step 1 3 Remove six I M3x6L screws...

Страница 63: ...56 SYSTEM SETUP Vecow EVS 2000 User Manual Step 2 Remove the four I M3x3L screws Step 3 Remove four I M3x6L screws Step 4 Open CPU slot Be careful CPU pin...

Страница 64: ...57 SYSTEM SETUP Step 5 Installing CPU on the slot and remove the mylar Step 6 Cover and lock the CPU socket...

Страница 65: ...58 SYSTEM SETUP Vecow EVS 2000 User Manual Step 7 Apply thermal grease like X Step 8 Cover the copper then fasten four I M3x3L screws and remove thermal pad mylar...

Страница 66: ...59 SYSTEM SETUP Step 9 Fasten four I M3x6L screws...

Страница 67: ...60 SYSTEM SETUP Vecow EVS 2000 User Manual 3 3 Installing DDR4 SO DIMM Modules Step 1 DDR4 RAM module into SO DIMM slot Step 2 Make sure the RAM module is locked by the memory slot...

Страница 68: ...61 SYSTEM SETUP 3 4 Installing Mini PCIe Card Step 1 Install Mini PCIe card into the Mini PCIe socket Step 2 Fasten one M2 5 screw...

Страница 69: ...62 SYSTEM SETUP Vecow EVS 2000 User Manual 3 5 Installing M 2 Key B E M 3 5 1 Key B 2280 Key E 2230 Key M 2280 Step 1 Install M 2 card into the M 2 slot Step 2 Fasten one PH M3x4L screw...

Страница 70: ...63 SYSTEM SETUP 3 5 2 Key B 3042 Step 1 Install M 2 card into the M 2 slot Step 2 Fasten one PH M3x4L screw...

Страница 71: ...SETUP Vecow EVS 2000 User Manual 3 5 3 Key B 3052 Step 1 Change the stud position Step 2 Then it is able to install M 2 Key B 3052 module Step 3 Install M 2 card into the M 2 slot and fasten one PH M3...

Страница 72: ...65 SYSTEM SETUP 3 6 Installing Antenna Cable Step 1 Remove the rubber corks on the front and side Step 2 Put antenna cable connector into the hole on panel...

Страница 73: ...66 SYSTEM SETUP Vecow EVS 2000 User Manual Step 3 Fasten washer on the antenna cable connector...

Страница 74: ...67 SYSTEM SETUP 3 7 Installing SIM Card Step 1 Remove two F M3x4L screws on SD SIM cover Step 2 Inserting SIM Card make sure the system power is not plugged...

Страница 75: ...68 SYSTEM SETUP Vecow EVS 2000 User Manual 3 8 Installing SD Card Step 1 Remove two F M3x4L screws on SD SIM cover Step 2 Inserting SIM Card make sure the system power is not plugged...

Страница 76: ...69 SYSTEM SETUP 3 9 Installing PCI PCIe Card Step 1 Check PCI PCIe Slot supports the maximum length 200 mm without card bracket of PCI PCIe expansion card Step 2 Remove one M3x5L and PCI bracket...

Страница 77: ...70 SYSTEM SETUP Vecow EVS 2000 User Manual Step 3 Installing PCI PCIe card and fasten M3x5L screws...

Страница 78: ...71 SYSTEM SETUP 3 10 Installing SSD HDD Step 1 Trigger and open SSD HDD tray Step 2 Insert 2 5 SSD HDD in the tray and fasten two F M3x4 screws...

Страница 79: ...72 SYSTEM SETUP Vecow EVS 2000 User Manual Step 4 Installing SSD HDD Step 3 Finish...

Страница 80: ...73 SYSTEM SETUP 3 11 Mounting Your EVS 2000 3 11 1 Wall Mount Bracket for EVS 2000 with four M3x6L screws 3 11 2 Wall Mount Bracket for EVS 2000F with four M3x6L screws...

Страница 81: ...74 SYSTEM SETUP Vecow EVS 2000 User Manual 3 11 3 EVS 2000 2000F VESA Mount Kit 75 x 75 100 x 100 mm Step 1 Remove six F M3x6L screws Step 2 Install VESA Mount and fasten six I M3x6L screws...

Страница 82: ...75 SYSTEM SETUP 3 11 4 EVS 2000 2000F Din Rail with VESA Mount Kit Step 1 Remove six F M3x6L screws Step 2 Install Din Rail with VESA Mount Kit and fasten six I M3x6L screws...

Страница 83: ...al 4 BIOS AND DRIVER 4 1 BIOS Settings BIOS provides an interface for users to check and change system configuration The BIOS setup program is accessed by pressing the Del key when POST display output...

Страница 84: ...System Date Set the date Use Tab to switch between date elements System Time Set the time Use Tab to switch between time elements Figure 4 2 BIOS Main Menu 4 3 Advanced Figure 4 3 BIOS Advanced Menu S...

Страница 85: ...ssor Cores Number of cores to enable in each processor package Hyper threading Enabled for Windows XP and Linux OS optimized for Hyper Threading Technology and disabled for other OS OS not optimized f...

Страница 86: ...ges to be supported Intel R Speed shift Technology Enable Disable Intel Speed Shift Technology support Enabling will expose the CPPCv2 interface to allow for hardware controlled P states Turbo Mode Tu...

Страница 87: ...KU Disable Turbo GT frequency Check to enable render standby support Figure 4 3 2 2 GT Power Management Control 4 3 3 PCH FW Configuration ME State Set ME to Soft temporarily disabled AMT BIOS Feature...

Страница 88: ...or disables system s ability to hibernate OS S4 sleep state This option may not be effective with some OS ACPI Sleep State Selects the highest ACPI sleep state the system will enter when the SUSPEND...

Страница 89: ...ings 4 3 7 1 Serial Port X Configuration Serial Port 1 to port 4 Configuration Options for Serial Port 1 to Serial Port 4 Entering the corresponding Port option then end user can change the settings s...

Страница 90: ...ng Smart Fan Support Smart Fan Support Work with Full Speed if Smart Fan Support is Disabled Smart Fan Mode Default Using the default smart fan table User Setting parameters by user Start Temperature...

Страница 91: ...ngs specify how the host computer and the remote computer which the user is using will exchange data Both computers should have the same or compatible settings Legacy Console Redirection Legacy Consol...

Страница 92: ...ing Figure 4 3 12 PCI Subsystem Settings Above 4G Decoding Globally Enables or Disables 64 bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports bot PCI Decoding Hot Plug...

Страница 93: ...e IPv4 HTTP boot support Ipv6 PXE Support Enable Disable IPv6 PXE boot support Ipv6 HTTP Support Enable Disable IPv6 HTTP boot support IP6 Configuration Policy Set IP6 Configuration Policy PXE boot wa...

Страница 94: ...s Storage Driver Support Enable disable USB mass storage driver support Port 60 64 Emulation Enables I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy supp...

Страница 95: ...native function BT Core This is an option intended to Enable Disable BT Core in CNVi BT Audio Offload This is an option to Enable Disable BT Audio Offload which enables audio input from BT device in...

Страница 96: ...4 3 18 SDIO Configuration Figure 4 3 18 SDIO Settings SDIO Access Mode Auto Access SD device in DMA mode if controller supports it otherwise in PIO mode DMA Access SD device in DMA mode PIO Access SD...

Страница 97: ...Configuration PCH parameters GPIOManager Configuration GPIOManager Configuration 4 4 Chipset 4 4 1 System Agent SA Configuration Figure 4 4 1 System Agent Settings VT d VT d capability Above 4GB MMIO...

Страница 98: ...ce should be Primary Display Or select SG for Switchable Gfx Internal graphics Keep IGFX enabled based on the setup options GTT Size Select the GTT Size Aperture Size Select the Aperture Size Note Abo...

Страница 99: ...Enable or disable onboard NIC Wake on LAN Enable or disable integrated LAN to wake the system The wake On LAN cannot be disabled if ME is on at Sx state Serial IRQ Mode Configure serial IRQ mode State...

Страница 100: ...e 4 4 2 1 PCH IO Settings DMI Link ASPM Control Enable Disable the control of Active State Power Management on SA side of the DMI Link Native PCIE Enable PCIE Express Native Support Enable Disable PCI...

Страница 101: ...the storage features Aggressive LPM Support Enable PCH to aggressively enter link power state Options for each SATA port Port n Enable or disable SATA Port Hot Plug Designated this port as Hot Pluggab...

Страница 102: ...nition pin Delay On Timer Second The delay times after user trigger ignition on signal Delay Off Timer Second The delay times after user trigger ignition off signal Force Shutdown Timer Minutes Used t...

Страница 103: ...AND DRIVER Vecow EVS 2000 User Manual Figure 4 5 BIOS Security Menu Administrator Password Set administrator password User Password Set user password Secure Boot Customizable Secure Boot Settings 4 5...

Страница 104: ...t HDD User Password option is gray do power cycle to enable the option again 4 5 2 Security Boot Figure 4 5 2 Security Boot Settings Attempt Secure Boot Secure Boot activated when Platform Key PK is e...

Страница 105: ...on key 65535 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Boot Option Sets the system boot order New Boot Opt...

Страница 106: ...ng the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save Changes done so far to any of the setup options Discard Changes Discard Changes done so far to...

Страница 107: ...ted DIO Definition Pin No Isolated DIO Definition Non Isolated DIO Definition 1 DI 0 DIO 0 11 DO 0 DIO 8 2 DI 1 DIO 1 12 DO 1 DIO 9 3 DI 2 DIO 2 13 DO 2 DIO 10 4 DI 3 DIO 3 14 DO 3 DIO 11 5 DI 4 DIO 4...

Страница 108: ...I Pin1 8 DIO Connector Source Mode PNP V V Power Supply 6 48V DC DI_COM Pin 9 DI Pin1 8 DIO Connector DO Reference Circuit V IO V Device 6 48V DC DIO_VDC Pin 20 DO Pin11 18 DIO_GND Pin10 19 DIO Connec...

Страница 109: ...er and Uninstall_32 bat and Uninstall_64 bat Uninstallation for driver Run batch file as Administrator Make sure Windows version before installation Header folders include head file for software devel...

Страница 110: ...103 Appendix A A 4 Sample Execute demo tool Sample as shown below Windows Linux Vecow_DIO Vecow_DIO_loopback Vecow_POE Vecow_WDT...

Страница 111: ...ot match BOOL get_IO1_configuration BYTE Iso BYTE DI_mode BYTE DO_ mode WORD Mask BOOL get_IO2_configuration BYTE Iso BYTE DI_mode BYTE DO_ mode WORD Mask Get DIO configuration by variable Isolate_Typ...

Страница 112: ...only for Non Isolated DIO GPIO 1 Output 0 Input Return TRUE 1 Success FALSE 0 Fail Initial error or hardware problem BOOL get_DIO1 BYTE DO_data BYTE DI_data BOOL get_DIO2 BYTE DO_data BYTE DI_data Get...

Страница 113: ...error or hardware problem BOOL get_WDT DWORD WDT Get watchdog timer setup WDT watchdog timer setup Unit second Range 0 65535 sec 1093 65535 min 65580 3932100 sec Return TRUE 1 Success FALSE 0 Fail In...

Страница 114: ...by hexadecimal bitmask 1 Auto 0 Manual Mask 3 0 DC Enable Disable pin setting by hexadecimal bitmask 1 Enable 0 Disable Return TRUE 1 Success FALSE 0 Fail Initial error or out of range error or call b...

Страница 115: ...mask 1 On 0 Off Return TRUE 1 Success FALSE 0 Fail Initial error or out of range error or call by pointer error or hardware problem BOOL set_POE BYTE ID BYTE POE Set POE state A ID POE ID Range 0 15 B...

Страница 116: ...vice to RAID mode on BIOS menu Chipset PCH IO Configuration SATAAnd RST Configuration SATA Mode Selection Intel RST Premium Save Changes and Reset C 1 2 UEFI Mode for RAID 1 Into BIOS menu again selec...

Страница 117: ...d with one M 2 key B one M 2 key M for NVME one mSATA slot and including two internal SATA We used SATA for Windows 10 OS installation as an example 3 Select disks to create RAID Volume then Save Chan...

Страница 118: ...an find the latest information and software directly from Intel s website http www intel com p en_US support highlights chpsts imsm The RAID environment has been done if you completed the steps above...

Страница 119: ...figure of SATA device allocation To start disk management tool select initialize disk Then add Logical Device for Windows access You will find Volume_0000 in SATA device at BIOS menu C 8 If One SATA H...

Страница 120: ...IFFERENT RAID HDD A warning will pop up to ask you if the disk is not a member of the original RAID volume If you press Rebuild it will replace the broken SATA HDD to the last SATA HDD of RAID volume...

Страница 121: ...d 3 0 8GB USB 4 USB Flash Transecnd 3 0 8GB USB 5 USB Flash Kingston 2 0 16GB USB 6 USB Flash Kingston 2 0 16GB M 2 M Key FORESEE FSGPMMC 256G 256GB SATA 0 HGST Z5K500 500 500GB LAN 1 i219 1 0 Gbps LA...

Страница 122: ...06W 0 921A 22 10W Core i5 10500E 36V 0 166A 05 98W 0 211A 07 59W 0 661A 23 78W Core i5 10500E 48V 0 147A 07 06W 0 188A 09 01W 0 543A 26 06W Core i5 10500E 50V 0 144A 07 22W 0 184A 09 18W 0 534A 26 70...

Страница 123: ...77W 0 252A 06 04W 0 835A 20 04W Core i9 10900TE 36V 0 169A 06 07W 0 213A 07 68W 0 673A 24 21W Core i9 10900TE 48V 0 149A 07 16W 0 189A 09 06W 0 541A 25 94W Core i9 10900TE 50V 0 146A 07 32W 0 186A 09...

Страница 124: ...1 357A 32 56W Core i5 10500E 36V 0 167A 06 00W 0 216A 07 77W 1 022A 36 80W Core i5 10500E 48V 0 147A 07 04W 0 189A 09 09W 0 810A 38 88W Core i5 10500E 50V 0 144A 07 20W 0 187A 09 35W 0 728A 36 40W CP...

Страница 125: ...0 253A 06 07W 1 313A 31 51W Core i5 10500E 36V 0 166A 05 98W 0 218A 07 85W 0 941A 33 88W Core i5 10500E 48V 0 147A 07 06W 0 190A 09 12W 0 775A 37 20W Core i5 10500E 50V 0 144A 07 20W 0 187A 09 35W 0 7...

Страница 126: ...1 172A 28 14W Core i5 10500E 36V 0 166A 05 98W 0 215A 07 74W 0 865A 31 14W Core i5 10500E 48V 0 147A 07 06W 0 189A 09 07W 0 668A 32 06W Core i5 10500E 50V 0 144A 07 20W 0 187A 09 35W 0 663A 33 15W CPU...

Страница 127: ...0 249A 05 98W 1 329A 31 90W Core i5 10500E 36V 0 168A 06 03W 0 212A 07 61W 0 969A 34 90W Core i5 10500E 48V 0 148A 07 11W 0 188A 09 03W 0 764A 36 68W Core i5 10500E 50V 0 144A 07 20W 0 186A 09 32W 0...

Страница 128: ...7W 1 297A 31 13W Core i5 10500E 36V 0 166A 05 98W 0 216A 07 78W 0 914A 32 90W Core i5 10500E 48V 0 144A 06 91W 0 186A 08 93W 0 719A 34 51W Core i5 10500E 50V 0 143A 07 15W 0 184A 09 20W 0 682A 34 10W...

Страница 129: ...mory Storage List E 1 Supported Memory List Testing Board EVS 2000 CPU version 5 1 Memory Test V5 01 BurnInTest V8 1 E 2 Test Item Channel Memory Test Burn In Flash BIOS Remove Battery 2 PASS PASS PAS...

Страница 130: ...GB DDR4 3200 W T SODIMM M4S0 AGS1O5EM H03 25 C 25 C Innodisk 16GB DDR4 2933 SODIMM M4S0 AGS1OCUN H03 25 C 25 C E 4 Supported Storage Device List Type Brand Model Capacity mSATA Toshiba THNSNS128GMCP 1...

Страница 131: ...fications are subject to change without prior notice No part of this publication may be reproduced in any form or by any means electric photocopying or recording without prior authorization from the p...

Отзывы: