50
GETTING TO KNOW YOUR EVS-2000
©Vecow EVS-2000 User Manual
2.6.2 Ignition Control Wiring
To activate ignition control, you need to provide IGN signal via the 3-pin pluggable
terminal block locates in the back panel. Please find below the general wiring
configuration.
For testing purpose, you can refer to the picture blow to simulate ignition signal
input controlled by a latching switch.
Note :
1. DC power source and IGN share the same ground.
2. EVS-2000 supports 9V to 50V wide range DC power input in ATX/AT mode. In
Ignition mode, the input voltage is fixed to 12V/24V for car battery scenario.
3. For proper ignition control, the power button setting should be "Power Down"
mode.
In Windows for
example, you need
to set "When I press
the power button" to
Shut down.
Pin No.
Definition
1
Ignition (IGN)
2
SW+
3
SW-
IGN
V+
Содержание EVS-2000 Series
Страница 59: ...52 SYSTEM SETUP Vecow EVS 2000 User Manual Step 3 Remove six F M3x4L screws Step 4 Take off the bottom cover...
Страница 60: ...53 SYSTEM SETUP Step 5 Finish...
Страница 62: ...55 SYSTEM SETUP Step 1 2 Remove fan module header Step 1 3 Remove six I M3x6L screws...
Страница 64: ...57 SYSTEM SETUP Step 5 Installing CPU on the slot and remove the mylar Step 6 Cover and lock the CPU socket...
Страница 66: ...59 SYSTEM SETUP Step 9 Fasten four I M3x6L screws...
Страница 70: ...63 SYSTEM SETUP 3 5 2 Key B 3042 Step 1 Install M 2 card into the M 2 slot Step 2 Fasten one PH M3x4L screw...
Страница 73: ...66 SYSTEM SETUP Vecow EVS 2000 User Manual Step 3 Fasten washer on the antenna cable connector...
Страница 77: ...70 SYSTEM SETUP Vecow EVS 2000 User Manual Step 3 Installing PCI PCIe card and fasten M3x5L screws...
Страница 79: ...72 SYSTEM SETUP Vecow EVS 2000 User Manual Step 4 Installing SSD HDD Step 3 Finish...