14
Connect the remote temperature sensor cable to the
interface
①
and place the other end close to the battery.
CAUTION:
If the remote temperature sensor is not connected
to the controller,, the default setting for battery charging or
discharging temperature is 25 °C without temperature
compensation.
Connect the accessories for RS485 communication
Refer to chapter4“Control Parameters Setting”.
Step 5:
Powered on the controller
Closing the battery fuse will switch on the controller. Then
check the status of the battery indicator (the controller is
operating normally when the indicator is lit in green).Close
the fuse and circuit breaker of the load and PV array.
Then the system will be operating in the preprogrammed
mode.
CAUTION:
If the controller is not operating properly or the
battery indicator on the controller shows an abnormality,
please refer to 5.2 “Troubleshooting”.